Classification According To Zvei, Cb24I - Pilz PSEN ml b 1.1 Operating Manual

Hide thumbs Also See for PSEN ml b 1.1:
Table of Contents

Advertisement

Classification according to ZVEI, CB24I

14
Classification according to ZVEI, CB24I
The following tables describe the classes and specific values of the product interface and
the classes of interfaces compatible with it. The classification is described in the ZVEI posi-
tion paper "Classification of Binary 24 V Interfaces - Functional Safety aspects covered by
dynamic testing".
Solenoid inputs
Drain
Safety switch
Drain parameters
Test impulse duration
Input resistance
Capacitive load
Safe 1-pole HL outputs
Source
Safety switch
Source parameters
Test impulse duration
Rated current
Capacitive load
Operating Manual PSEN ml b 1.1/2.1/2.2
1003884-EN-12
Source
C2
Safety control system
Min.
Typ.
-
-
16 Ohm
-
-
-
Drain
C2
Evaluation device
Min.
Typ.
-
-
-
-
-
-
C2, C3
Max.
500 µs
1,5 nF
C1, C2
Max.
450 µs
0,1 A
70 nF