beams, wall studs, water pipes or electrical wiring. It may be easier to relocate the fireplace than to rework
the building structure. Also choose a location that allows installing the least amount of offsets in the
chimney.
Usually, no additional floor support is needed for the fireplace. The adequacy of the floor can be checked
by first estimating the weight of the fireplace system. Weights are given in the section Erreur ! Source du
renvoi introuvable. - Erreur ! Source du renvoi introuvable.. Next, measure the area occupied by the
fireplace. Note the floor construction and consult your local building code to determine if additional support
is needed.
THE FIREPLACE MUST BE INSTALLED ON A LEVEL AND STRAIGHT (NOT UNEVEN) SURFACE.

6.3.4 CLEARANCES TO COMBUSTIBLE MATERIALS

The clearances shown in this section have been determined by test according to procedures set out in
safety standards ULC-S610 (Canada) and UL 127 (U.S.A.). When the fireplace is installed so that its
surfaces are at or beyond the minimum clearances specified, combustible surfaces will not overheat under
normal and even abnormal operating conditions.
NO PART OF THE FIREPLACE MAY BE LOCATED CLOSER TO COMBUSTIBLES THAN THE MINIMUM
CLEARANCE FIGURES GIVEN.
HearthStone Quality Home Heating Products, Inc ®
WARNING
WARNING
26
CLEARANCES*
A
6" (152 mm) max
B
8" (203 mm) min
C
24" (610 mm) min
*Measurements are from the
door opening.
Wall in front of fireplace: 48"
Ceiling: 84" (2.13 m) measured
from the base of the fireplace.
Fireplace enclosure:
Back : 0"
Sides : 0"
Floor (under the fireplace): 0"
Chimney: 2" (50 mm)
WFP-100 Model 8420