Combustible Surface Required Clearances - HearthStone Manchester 8360 Owner's Manual

Installation and operating instructions
Table of Contents

Advertisement

C
S
OMBUSTIBLE
URFACE
Note: Dimensions shown in the following figures are from the body of the stove unless otherwise indicated.
It is very important to follow minimum clearances for chimney connectors to combustibles such as walls and
ceilings when installing the stove near combustible surfaces.
Clearances
Single wall Connector –
Single Wall Connector –
Double Wall Connector –
Double Wall Connector –
Alcove Clearances (inches)
Minimum alcove width
Maximum alcove depth
Min. Alcove ceiling from floor with single wall connector 68" – 173cm
Min. Alcove ceiling from floor with double wall connector 64" – 163cm
*SIDE WITH DOOR MUST BE 18" FROM SIDE WALL UNLESS THE SIDE DOOR LOCKING KIT IS
INSTALLED. CONSIDER SPACE FOR LOADING OF STOVE USING THE SIDE DOOR.
FOR CLOSE CLEARANCE HEAT SHIELD, USE KIT #93-68600
Hearthstone Quality Home Heating Products, Inc ®
R
C
EQUIRED
Figure 3 – Clearance to Combustibles
No Close Clearance Heat Shield
With Close Clearance Heat Shield
No Close Clearance Heat Shield
With Close Clearance Heat Shield
LEARANCES
Parallel
*A
B
18"-46cm 16"-41cm 21"-54cm 33.625"-86cm
18"-46cm 10"-26cm 15"-39cm 33.625"-86cm
16"-41cm 16"-41cm 21"-54cm 31.625"-81cm
16"41cm 6"-16cm
Unprotected Surfaces Protected Surfaces (NFPA-211)
62.25" – 159cm
52" – 132cm
9
C
D
11"-28cm 31.625"-81cm
See NFPA-211
See NFPA-211
See NFPA-211
See NFPA-211
Manchester Model 8360
Corner
E
9"-23cm
9"-23cm
9"-23cm
9"-23cm