8.7 ANGLED WALL RADIATION SHIELD

When passing through a combustible wall with
the chimney at a 30 or 45 angle (30 or 45 in
Canada and 30 only in the USA), an angled
firestop or wall radiation shield provided by the
chimney manufacturer must be installed. Only
one
is
required.
manufacturer's installation instructions.
In cold climate locations, it is recommended
that you use the insulated wall radiation shield
since it will maintain the home's thermal
barrier.
8.8 CHIMNEY
INSTALLATION

8.8.1 UNIVERSAL ROOF SUPPORT

This support has three possible uses:
1. It must be used on a roof to support the chimney.
2. It may be used on a floor, ceiling or roof above an offset to support the chimney above the offset.
3. It may be used on a floor, ceiling or roof as a supplementary support.
For roof support installation, refer to the instructions provided with the support by the chimney
manufacturer. Many manufacturers will provide the maximum height of chimney that can be supported
by the support. Make sure you respect those parameters.
HearthStone Quality Home Heating Products, Inc ®
TABLE 4 – LIST OF MANDATORY COMPONENTS
MANDATORY COMPONENTS
 Ventilated roof flashing.
 Rafter protector at the roof level is chimney is enclosed at the attic level.
 Ventilated roof flashing.
 Must have rafter protectors at the roof level if the chimney is enclosed at
the attic level.
 Rafter protector at the roof level if chimney is enclosed at the attic level.
 Requires insulated attic radiation shield unless chimney is enclosed at the
attic level.
 Ventilated roof flashing.
 Rafter protector at the roof level is chimney is enclosed at the attic level.
 Chimney cannot be enclosed at the attic level.
Follow
the
chimney
SUPPORT
10.44"
46
TYPE/BRAND
1" Solid Pack
CF Sentinel (CF),
Super Pro 2100 (ALT),
Super Vent 2100 (JM)
2" Solid Pack : S-2100+
2" Solid Pack : Dura Plus
HTC,
AC Triple Wall: Dura Plus
AC Triple wall HS,
AC Triple wall HSS
1.530"
5.126"
.512"
INSULATED WALL
A
RADIATION SHIELD
B
GYPROCK
INSULATED WALL
C
WFP-100 Model 8420