6.2 REGULATIONS COVERING FIREPLACE INSTALLATION

When installed and operated as described in these instructions, the WFP-100 wood fireplace is suitable for
use in residential installations.
In Canada, the CSA B365 Installation Code for Solid Fuel Burning Appliances and Equipment and the CSA
C22.1 Canadian National Electrical Code are to be followed in the absence of local code requirements. In
the USA, the ANSI NFPA 211 Standard for Chimneys, Fireplaces, Vents and Solid Fuel-Burning Appliances
and the ANSI NFPA 70 National Electrical Code are to be followed in the absence of local code
requirements.
THE FIREPLACE IS NOT APPROVED FOR USE WITH A SO-CALLED "POSITIVE FLUE CONNECTION"
TO THE CLAY TILE OF A MASONRY CHIMNEY.

6.3 FIREPLACE INSTALLATION

6.3.1 STANDOFF INSTALLATION

BEFORE INSTALLING YOUR FIREPLACE, YOU MUST INSTALL THE TWO STANDOFFS ON THE
SIDE AND THE TWO STANDOFFS ON THE BACK OF THE FIREPLACE.
The standoffs are in the firebox of the fireplace and the screws are with the manual kit. Using the screws
provided, install two standoffs on each side and two standoffs on the back of the fireplace.
Side standoffs

6.3.2 TRANSPORTATION PACKAGING

To facilitate transportation of the WFP-100 fireplace before installation, we have designed a transportation
packaging that allows reducing the weight. The fireplace refractory panels are in a box you can carry
separately. We suggest you install the refractory panels after the setting up of the fireplace. To install the
refractory panels, see

6.3.3 LOCATING THE WFP-100

The best location to install your fireplace is determined by considering the location of windows, doors, and
the traffic flow in the room where the fireplace is located, allowing space in front of the unit for the heart
extension and the mantel, and taking into consideration the location of the hot air ducts (optional), outside
air kit and chimney. If possible, choose a location where the vent will not interfere with any truss, roof
HearthStone Quality Home Heating Products, Inc ®