5.2.5 CHIMNEY FIRE

Regular chimney maintenance and inspection can prevent chimney fires. If you have a chimney fire, follow
these steps:
1. Close the fireplace door and the air intake controls;
2. Alert your family of the possible danger;
3. If you require assistance, alert your fire department;
4. If possible, use a dry chemical fire extinguisher, baking soda or sand to control the fire.
Do not use water as it may cause a dangerous steam explosion;
5. Check outside to ensure that sparks and hot embers coming out of the chimney are not
igniting the roof;
6. Do not use the fireplace again until your chimney and fireplace have been inspected by
a qualified chimney sweep or a Fire Department Inspector.
PART B – INSTALLATION
Install the fireplace only as described in these instructions and using only components from the chimney
manufacturers listed in table 3.
Parts Required
WFP-100 Fireplace
Traditional style faceplate - metallic black
Classic moulded refractory brick panels
Insulated chimney made by the manufacturers listed in table 3, with the corresponding specifications :
Chimney lengths
Elbows (where necessary)
Associated components as per these installation instructions.
Additional Equipment (optional)
Forced air distribution kit
Insulated flex pipe for forced air distribution kit
Warm air circulation grille - modern style

6 SAFETY INFORMATION

6.1 SUMMARY OF INSTALLATION CAUTIONS AND
WARNINGS
THE INFORMATION GIVEN ON THE CERTIFICATION LABEL AFFIXED TO
THE APPLIANCE ALWAYS OVERRIDES THE INFORMATION PUBLISHED,
IN ANY OTHER MEDIA (OWNER'S MANUAL, CATALOGUES, FLYERS,
MAGAZINES AND/OR WEB SITES).
MIXING OF APPLIANCE COMPONENTS FROM DIFFERENT SOURCES
OR MODIFYING COMPONENTS MAY RESULT IN HAZARDOUS
CONDTIONS.
ANY MODIFICATION OF THE APPLIANCE THAT HAS NOT BEEN
APPROVED IN WRITING BY THE TESTING AUTHORITY VIOLATES CSA
B365 (CANADA), AND ANSI NFPA 211 (USA).
IF REQUIRED, A SUPPLY OF COMBUSTION AIR SHALL BE PROVIDED
TO THE ROOM.
DO NOT CONNECT TO OR USE IN CONJUNCTION WITH ANY AIR DISTRIBUTION DUCTWORK.
DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE SERVING ANOTHER APPLIANCE.
THIS FIREPLACE HAS NOT BEEN TESTED TO BE INSTALLED IN A MOBILE HOME.
THIS FIREPLACE HAS NOT BEEN TESTED TO BE INSTALLED INSIDE A MASONRY CHIMNEY.