Description - Siemens SIMATIC NET RUGGEDCOM i802 Installation Manual

Rugged ethernet
Table of Contents

Advertisement

Introduction
1.2 Description
Rated for Reliability in Harsh Environments
Memory Options
Power Supply
1.2

Description

The RUGGEDCOM i802 features various ports, controls and indicator LEDs on the
front panel for connecting, configuring and troubleshooting the device.
1
2
3
1
2
3
4
5
6
7
8
2
VLAN (802.1Q) to segregate and secure network traffic
RADIUS centralized password management
SNMPv3 authentication and 56-bit encryption
Immunity to EMI and heavy electrical surges
Hazardous Location Certification: Class I, Division 2
-20 to +60 °C (-4 to 140 °F) operating temperature (optional -40 to +85°C or -40
to 185 °F)
Conformal coated printed circuit boards (optional)
Die cast aluminum enclosure
Removable microSD/microSDHC card
Dual low-voltage DC inputs: 24 VDC (9-32 VDC)
Compression fit connections
CSA/UL 60950 safety approved to 85 °C (185 °F)
5
4
7
Failsafe Alarm Relay
Power Supply Terminal Block
Chassis Ground Terminal
POWER LEDs
ALARM LED
Port Status LED
Fiber Optic or Copper Gigabit Ethernet Ports
Copper Ethernet Ports
6
8
9
10
RUGGEDCOM i802
Installation Manual, 01/2021, C79000-G8976-1004-06