6.1.10 Other Approvals; Emc And Environmental Type Tests - Siemens SIMATIC NET RUGGEDCOM i802 Installation Manual

Rugged ethernet
Table of Contents

Advertisement

6.1.10
Other Approvals
This device meets the requirements of the following additional standards:
6.2

EMC and Environmental Type Tests

The RUGGEDCOM i802 has passed the following EMC and environmental tests.
IEC 61850-3 Type Tests
IEC 61000-4-2
IEC 61000-4-3
IEC 61000-4-4
IEC 61000-4-5
IEC 61000-4-6
IEC 61000-4-8
IEC 61000-4-29
IEC 61000-4-12
IEC 61000-4-16
IEC 61000-4-17
IEEE 1613 EMC Immunity Type Tests
RUGGEDCOM i802
Installation Manual, 01/2021, C79000-G8976-1004-06
IEC 61000-6-2
Electromagnetic Compatibility (EMC) – Part 6-2: Generic Standards – Immunity
for Industrial Environments
Test
Radiated RFI
Burst (Fast Transient)
Induced (Conducted) RFI
Magnetic Field
Voltage Dips
Damped Oscillatory
Mains Frequency Voltage
Ripple on DC Power Supply
Description
ESD
Enclosure Contact
Radiated RFI
Description
ESD
Enclosure
Contact
Enclosure Air
Enclosure ports
Signal ports
DC Power ports
Surge
Signal ports
DC Power ports
Signal ports
DC Power ports
ground ports
Enclosure ports
DC Power ports
Signal ports
DC Power ports
Signal ports
DC Power ports
DC Power ports
Enclosure Air
Enclosure ports
6.1.10 Other Approvals
Test Levels
± 4 kV
± 8 kV
± 8 kV
20 V/m
± 4 kV @ 5 kHz
± 4 kV @ 5 kHz
± 1 kV line-to-earth
± 0.5 kV line-to-earth/line
Earth
30 A/m
30% reduction for 0.3 seconds
60% reduction for 1 second
2.5 kV common, 1 kV
differential mode @ 1 MHz
2.5 kV common, 1 kV
differential mode @ 1 MHz
10 V Continuous, 100 V for 1 s
10 V Continuous, 100 V for 1 s
± 15%
Test Levels
± 8 kV
± 8 kV
35 V/m
Certification
10 V