Connection to LA amplied controllers
Enclosure drive capacity per amplied controller
Make sure the total number of connected enclosures does not exceed the maximum number of enclosures per controller
(refer to the footnotes).
Refer to the Amplication reference technical bulletin for the latest information on compatibility with amplied
controllers and cabling schemes for all enclosure types.
X12
Cabling schemes for X12
Refer to the cabling schemes to connect the enclosures to different types of output connectors.
One-channel speakON output
1+/1-
Two-channel speakON output
SP
CC4FP
1+/1-
2+/2-
Four-channel CA-COM output
DO
*
For passive loudspeakers, the value corresponds to the number of enclosures in parallel on the output. For active
loudspeakers, the value corresponds to the number of sections in parallel on the output.
X12 owner's manual (EN) version 1.0
LA4X
*
per output
/ total
1 / 4
SP
SP
CH(1)
SP-Y1
SP
CH(2)
SPK1
SP
SPK2
SPK3
SPK4
LA8
*
per output
/ total
2 / 8
Connection to LA amplied controllers
LA12X
*
per output
/ total
3 / 12
73