L-Acoustics X12 Owner's Manual
Hide thumbs Also See for X12:

Advertisement

X12
owner's manual (EN)

Advertisement

Table of Contents
loading

Summary of Contents for L-Acoustics X12

  • Page 1 owner's manual (EN)
  • Page 2 Document reference: X12 owner's manual (EN) version 1.0 Distribution date: May 18, 2021 © 2021 L-Acoustics. All rights reserved. No part of this publication may be reproduced or transmitted in any form or by any means without the express written consent of the publisher.
  • Page 3: Table Of Contents

    Mechanical safety.............................24 Loudspeaker congurations..........................26 X12 point source...........................26 X12 point source with LF.........................27 X12 with SB15m...........................27 X12 with SB18..........................28 X12 with KS21..........................29 X12 stage monitor..........................30 Low-latency preset......................... 30 X12 stage monitor with LF........................31 X12 with SB15m...........................31...
  • Page 4 X12 with SB18..........................32 X12 with KS21..........................33 Inspection and preventive maintenance....................... 34 How to do preventive maintenance......................34 Rigging part inspection........................... 35 Mechanical system overview........................35 Inspection references..........................40 Acoustical check............................. 42 Rigging procedures............................46 Mounting on a U-bracket.........................46 Using a U-bracket with X-UTILT......................... 50 Flying with a U-bracket...........................
  • Page 5: Safety

    Respect the Working Load Limit (WLL) of third party equipment. L-Acoustics is not responsible for any rigging equipment and accessories provided by third party manufacturers. Verify that the Working Load Limit (WLL) of the suspension points, chain hoists and all additional hardware rigging accessories is respected.
  • Page 6 This system is intended for use by trained personnel for professional applications. As part of a continuous evolution of techniques and standards, L-Acoustics reserves the right to change the specications of its products and the content of its documents without prior notice.
  • Page 7: Introduction

    The L-Vents laminar vented ports reduce turbulence and port noise at high levels to increase LF efciency. The X12 operates from 59 Hz to 20 kHz. The coaxial transducer arrangement and its ellipsoid acoustic design produce a 90° × 60° directivity pattern with a smooth tonal response free of secondary lobes over the entire frequency range.
  • Page 8: System Components

    Refer to the LA4X / LA8 / LA12X owner's manual for detailed instructions about the whole cabling scheme, including modulation cables and network. Rigging elements X-UL12 Long U-bracket for X12 X-US1215 Short U-bracket for X12 and X15 HiQ X-UTILT U-bracket wallmount for X series with tilt adjustment X-BAR Rigging bar for 1 enclosure EMBi...
  • Page 9: Loudspeaker Cables

    0.7 m / 5 m / 10 m / 25 m CH(1) CH(2) SP.7 / SP5 / SP10 / SP25 SP-Y1 SPK1 SPK2 0.7 m / 10 m / 25 m SPK3 SPK4 DO.7 / DO10 / DO25 DOSUB-LA8 X12 owner's manual (EN) version 1.0...
  • Page 10: Rigging Elements

    System components Rigging elements EMBi X-UTILT X-BAR X-UL12 X-US1215 CLAMP250 X12 owner's manual (EN) version 1.0...
  • Page 11: Electro-Acoustical Description

    −60 −80 −100 −120 −140 −160 −180 1 000 10 000 Frequency (Hz) Dispersion angle diagram of a single X12 system using lines of equal sound pressure at -3 dB, -6 dB, -12 dB. X12 owner's manual (EN) version 1.0...
  • Page 12: Monitor Angles

    Electro-acoustical description Monitor angles X12 system features risers that allow to change the monitor angle from 35° to 55°. 55° 35° Preset description [X12] [X12_MO] outputs channels routing gain delay polarity mute OUT 1 IN A 0 dB 0 ms...
  • Page 13: Connectors

    Electro-acoustical description Connectors SpeakON connectors can be used interchangeably as IN or LINK connector. 2 × 4-point speakON Internal pinout for L-Acoustics 2-way passive enclosures speakON points Transducer connectors + Not linked Not linked X12 owner's manual (EN) version 1.0...
  • Page 14: Rigging System Description

    Rigging system description X12 system X12 system features a M8 DIN580 threaded insert designed to implement a secondary safety. The logo on the enclosure front can be rotated to adapt to every conguration. X12 system features ergonomic handles on both sides for easy transportation.
  • Page 15 Rigging system description X12 system features four runners on the bottom to protect the enclosure. X12 system features risers that allow to change the monitor angle from 35° to 55° relative to the vertical. CLICK! X12 owner's manual (EN) version 1.0...
  • Page 16: Elements For Ying And Wall-Mounting

    X-US1215 and X-UL12 X12 system can be tted with a short U-bracket, X-US1215, or a long U-bracket, X-UL12. The brackets are secured in the enclosure inserts with two threaded knobs. A spring-lock safety mechanism secures the knobs in the U-brackets.
  • Page 17 Rigging system description X-US1215 and X-UL12 can be used for wall-mounting, ceiling-mounting or ying X12 system. Short U-bracket in horizontal position In this position, the enclosure applies a diagonal force of 405 daN on the anchoring points. Fasteners for wall-mounting or ceiling-mounting Secure the bracket with three M10 screws.
  • Page 18 When using the additional holes, consider the maximum site angle available. Maximum angles (p.60). X-US1215 features additional holes on the sides to closely t the enclosure and to optimize visual impact. The knobs shall be stored in the U-brackets. X12 owner's manual (EN) version 1.0...
  • Page 19: X-Utilt

    5° steps. The azimuth angle can be adjusted with the U-bracket. X-UTILT shall only be used vertically. Fasteners for wall-mounting Secure the X-UTILT with two M10 screws. Select screw length and anchors applicable to the wall properties. X12 owner's manual (EN) version 1.0...
  • Page 20: X-Bar

    X-BAR is a rigging bar for ying . The rigging system consists of a threaded axis with a cam lever. X-BAR is secured to the dedicated inserts on the enclosure, in front or rear extension position. Five angulation holes are available. X12 owner's manual (EN) version 1.0...
  • Page 21 Rigging system description X-BAR is compatible with a Ø12 mm shackle WLL 1 t (provided) and with CLAMP250. X12 owner's manual (EN) version 1.0...
  • Page 22: Elements For Pole-Mounting

    Rigging system description Elements for pole-mounting Pole sockets X12 features two 35 mm pole sockets integrated in the handles. EMBi EMBi is a pole-mount adapter for X-US1215 (35 mm pole). The site angle can be adjusted with the U-bracket. X12 owner's manual (EN) version 1.0...
  • Page 23: Subwoofers

    Use a 35 mm diameter pole The pole can be non-threaded or with M20 thread. Use an adapter for poles with other dimensions, for example the 21329 adapter by K&M, available on www.k ‑ m.de/en. X12 owner's manual (EN) version 1.0...
  • Page 24: Mechanical Safety

    Mechanical safety Flown congurations The X12 system rigging system complies with 2006/42/EC: Machinery Directive. It has been designed following the guidelines of BGV-C1. 2006/42/EC: Machinery Directive species a safety factor of 4 against the rupture. The own deployments described in this manual achieve a safety factor of 5 or more.
  • Page 25 Soundvision calculations are based on usual environmental conditions. A higher safety factor is recommended with factors such as extreme high or low temperatures, strong wind, prolonged exposition to salt water, etc. Always consult a rigging specialist to adopt safety practices adapted to such a situation. X12 owner's manual (EN) version 1.0...
  • Page 26: Loudspeaker ConGurations

    Loudspeaker congurations X12 point source Deployed as a standalone point source, an X12 system operates over the nominal bandwidth of the X12 enclosure. The [X12] preset allows for a reference frequency response in short throw applications. The X12 enclosure is driven by the LA4X / LA8 / LA12X amplied controllers.
  • Page 27: X12 Point Source With Lf

    The X12, SB15m, SB18 and KS21 enclosures are driven by the LA4X / LA8 / LA12X amplied controllers. X12 with SB15m With SB15m, the X12 system contour is reinforced by 8 dB at 100 Hz and the system bandwidth is extended down to 40 Hz.
  • Page 28: X12 With Sb18

    Loudspeaker congurations X12 with SB18 With SB18, the X12 system contour is reinforced by 4 dB at 60 Hz and 5 dB at 100 Hz, and the system bandwidth is extended down to 32 Hz. Values and ratios are the same for SB18 IIi.
  • Page 29: X12 With Ks21

    Loudspeaker congurations X12 with KS21 With KS21, the X12 system contour is reinforced by 6 dB at 60 Hz and 2 dB at 100 Hz, and the system bandwidth is extended down to 31 Hz. Values and ratios are the same for KS21i. KS21i is not mechanically compatible with pole-mounted congurations.
  • Page 30: X12 Stage Monitor

    Low-latency preset A low-latency preset is available for the X12 system enclosure used as a monitor ([X12_MO]). It reduces latency from 3.84 ms down to 1.18 ms (LA8) and 0.84 ms (LA4X / LA12X). If the monitor is combined with a subwoofer, a custom preset must be used.
  • Page 31: X12 Stage Monitor With Lf

    The X12, SB15m, SB18 and KS21 enclosures are driven by the LA4X / LA8 / LA12X amplied controllers. X12 with SB15m With SB15m, the X12 system contour is reinforced by 8 dB at 100 Hz and the system bandwidth is extended down to 40 Hz.
  • Page 32: X12 With Sb18

    Loudspeaker congurations X12 with SB18 With SB18, the X12 system contour is reinforced by 4 dB at 60 Hz and 5 dB at 100 Hz, and the system bandwidth is extended down to 32 Hz. Values and ratios are the same for SB18 IIi.
  • Page 33: X12 With Ks21

    Loudspeaker congurations X12 with KS21 With KS21, the X12 system contour is reinforced by 6 dB at 60 Hz and 2 dB at 100 Hz, and the system bandwidth is extended down to 31 Hz. Values and ratios are the same for KS21i. 55°...
  • Page 34: Inspection And Preventive Maintenance

    Mechanical system overview (p.35) to identify critical parts of the system and apply the specic checks described in the Inspection references (p.40). If any parts are damaged, contact your L-Acoustics representative for further instructions. Acoustics Perform the Enclosure check (p.42).
  • Page 35: Rigging Part Inspection

    • rigging elements integrated in the product such as rigging arms and rails • transportation accessories This inspection procedure covers only L-Acoustics products. To inspect other products that are part of the lifting chain, refer to the manufacturer's instructions. Prerequisite Perform the inspection in a well-lit environment.
  • Page 36 Threaded knobs (p.40) the inserts are not damaged X12 with X-US1215 and X-UTILT the supporting screws are tightened the inserts are not damaged Threaded knobs (p.40) the axes are tightened and not bent X12 owner's manual (EN) version 1.0...
  • Page 37 X12 pole-mounted the pole-socket is not damaged X12 owner's manual (EN) version 1.0...
  • Page 38 Inspection and preventive maintenance X12 pole-mounted with X-US1215 and EMBi on SB18 the inserts are not damaged Threaded knobs (p.40) the screws are tightened the wing knob is tightened Pole-mount socket (p.41) X12 owner's manual (EN) version 1.0...
  • Page 39 Inspection and preventive maintenance X12 on the ground Runners and risers (p.40) Runners and risers (p.40) X12 owner's manual (EN) version 1.0...
  • Page 40: Inspection References

    Runners and risers • Runners are not worn out. • Risers are not damaged and move correctly. • Screws are tightened. Reference pictures Contact your L-Acoustics representative for repair instructions. Related tasks Rigging part inspection (p.35) Threaded knobs • Head part does not have cracks.
  • Page 41 Pole-mount socket • Pole-mount socket is not damaged or bent. • Screws are tightened. • Socket plug is present. Reference pictures Contact your L-Acoustics representative for repair instructions. Related tasks Rigging part inspection (p.35) X12 owner's manual (EN) version 1.0...
  • Page 42: Acoustical Check

    6. Press the OK key or the encoder wheel to launch the ENCLOSURE CHECK. The amplied controller generates short sinusoidal signals simultaneously for each connected output. The amplied controller displays the results for each output. X12 owner's manual (EN) version 1.0...
  • Page 43 • a percentage of variation from the expected range (found in NOK and UNDEF results) • the number of operational transducers out of the total Low variations from the expected range are acceptable: displayed percentage can be different from 0 and all transducers considered operational. X12 owner's manual (EN) version 1.0...
  • Page 44 4. Carefully clean the speaker with a dry cloth. 5. Perform the reassembly procedure. Replace the speaker gasket and the screws. Apply the recommended torque. 6. Repeat the listening test. If the problem persists, replace the speaker. X12 owner's manual (EN) version 1.0...
  • Page 45 Apply the recommended torque. 5. Repeat the listening test. If a buzzing sound is still audible, it might be necessary to add an extra shim on the air gap. If the problem persists, replace the driver. X12 owner's manual (EN) version 1.0...
  • Page 46: Rigging Procedures

    The same procedure applies for X-UL12 in vertical position or in ceiling-mounting conguration and X-US1215 in horizontal or vertical position or in ceiling-mounting conguration. Assembly Procedure 1. Drive the knobs in the inserts on the enclosure. Stop when the threading is halfway in. X12 owner's manual (EN) version 1.0...
  • Page 47 3. Lift the enclosure by the knobs and place it inside the U-bracket. Adjust the knobs on both sides so that the safety washer is between the hook and the enclosure. 4. Push until the knobs are locked inside the spring-lock safety mechanism. SHLAK! X12 owner's manual (EN) version 1.0...
  • Page 48 Rigging procedures 5. Set the site angle. Use the screw as a reference point to read the label. 6. Tighten the knobs. Make sure the enclosure is steady. X12 owner's manual (EN) version 1.0...
  • Page 49 Do not unscrew the knobs all the way. 2. On both sides, pull on the safety mechanism while lifting the enclosure by the knobs to release it. 3. Remove the U-bracket from the wall. X12 owner's manual (EN) version 1.0...
  • Page 50: Using A U-Bracket With X-Utilt

    X-UTILT shall only be used vertically. Fasteners for wall-mounting Secure the X-UTILT with two M10 screws. Select screw length and anchors applicable to the wall properties. 1. Secure X-UTILT to the wall using M10 screws. X12 owner's manual (EN) version 1.0...
  • Page 51 Rigging procedures 2. Secure the U-bracket to X-UTILT. 3. Secure the rigging arm to the U-bracket. Make sure the rigging arm is in the correct position. Always use the central insert. X12 owner's manual (EN) version 1.0...
  • Page 52 Refer to the angles on the label. 0° -5° -10° -15° -20° -25° 30° -35° -40° -45° 5. Drive the knobs in the inserts on the enclosure. Stop when the threading is halfway in. X12 owner's manual (EN) version 1.0...
  • Page 53 6. Lift the enclosure by the knobs and place it inside the U-bracket. Adjust the knobs on both sides so that the safety washer is between the hook and the enclosure. 7. Push until the knobs are locked inside the spring-lock safety mechanism. X12 owner's manual (EN) version 1.0...
  • Page 54 Rigging procedures 8. Set the azimuth angle. Use the screw as a reference point to read the label. 9. Tighten the knobs. Make sure the enclosure is steady. X12 owner's manual (EN) version 1.0...
  • Page 55 Do not unscrew the knobs all the way. 2. On both sides, pull on the safety mechanism while sliding the enclosure out of the U-bracket. 3. Remove the U-bracket and X-UTILT from the wall. X12 owner's manual (EN) version 1.0...
  • Page 56: Flying With A U-Bracket

    1. Drive the knobs in the inserts on the enclosure. Stop when the threading is halfway in. 2. Place the U-bracket around the assembly. Adjust the knobs on both sides so that the safety washer is between the hook and the enclosure. X12 owner's manual (EN) version 1.0...
  • Page 57 3. Push down until the knobs are locked inside the spring-lock mechanism. SHLAK! Alternatively, use the additional holes on the U-bracket. The hooks on the bracket must be oriented towards the front of the enclosure. X12 owner's manual (EN) version 1.0...
  • Page 58 Rigging procedures Make sure the safety washer goes through the hole on the bracket. 4. Tighten the knobs and y the enclosure with a clamp. X12 owner's manual (EN) version 1.0...
  • Page 59 Rigging procedures 5. Loosen the knobs to set the site angle. Use the screw as a reference point to read the label. X12 owner's manual (EN) version 1.0...
  • Page 60 Rigging procedures 6. Tighten the knobs. Make sure the enclosure is steady. Maximum angles When using the additional holes on the U-bracket, consider the maximum negative site angle available. -40° -30° -15° X12 owner's manual (EN) version 1.0...
  • Page 61 Rigging procedures Disassembly Procedure 1. Place the enclosure on a at surface. 2. Loosen the knobs. 3. Pull on the safety mechanism and remove the U-bracket from the enclosure. X12 owner's manual (EN) version 1.0...
  • Page 62: Flying With X-Bar

    When ying an enclosure or an array, use the M8 DIN580 threaded insert to implement a secondary safety. Assembly Procedure 1. Lay the enclosure on a at surface. 2. Drive the X-BAR in the insert. X12 owner's manual (EN) version 1.0...
  • Page 63 3. Rotate the X-BAR until perpendicular to the front grill. Use the screws as reference points. 4. Tighten the X-BAR. a) Lift the lever and rotate it counter-clockwise, release the lever and rotate it clockwise. Repeat until the X-BAR is tightly secured. X12 owner's manual (EN) version 1.0...
  • Page 64 Rigging procedures b) Finally, store the lever on the right. X12 owner's manual (EN) version 1.0...
  • Page 65 -14.5° • Front extension on horizontal enclosure +23° +14° +4° +31.5° +40° • Rear extension on vertical enclosure +3° -5° +10.5° -13° -20.5° • Front extension on vertical enclosure +2° +10° -6° +17° +25° X12 owner's manual (EN) version 1.0...
  • Page 66 Rigging procedures 6. Lift the assembly. X12 owner's manual (EN) version 1.0...
  • Page 67 Rigging procedures Disassembly Procedure 1. Take down the assembly. 2. Lift the lever and rotate it clockwise. 3. Release the lever and rotate it counter-clockwise. 4. Repeat until the X-BAR can be removed. X12 owner's manual (EN) version 1.0...
  • Page 68: Pole-Mounting With A U-Bracket

    1. Secure EMBi to the U-bracket with the provided bolts and nuts. 2. Secure the U-bracket to the enclosure using the additional holes. The hooks on the bracket must be oriented towards the front of the enclosure. X12 owner's manual (EN) version 1.0...
  • Page 69 Rigging procedures Make sure the safety washer goes through the hole on the bracket. 3. Tighten the knobs, reverse the assembly and mount it on a pole. 4. Tighten EMBi. X12 owner's manual (EN) version 1.0...
  • Page 70 Rigging procedures 5. Loosen the knobs to set the site angle. Consider the maximum positive site angle available. Maximum angles +40° +30° +15° X12 owner's manual (EN) version 1.0...
  • Page 71 Rigging procedures 6. Tighten the knobs. Make sure the enclosure is steady. The assembly can be mounted on a tripod or on a subwoofer. X12 owner's manual (EN) version 1.0...
  • Page 72 About this task Remove the assembly from the pole before disassembling the enclosure and the bracket. Procedure 1. Loosen EMBi to remove the assembly from the pole. 2. Remove the bracket from the enclosure. X12 owner's manual (EN) version 1.0...
  • Page 73: Connection To La AmpliEd Controllers

    SPK3 SPK4 For passive loudspeakers, the value corresponds to the number of enclosures in parallel on the output. For active loudspeakers, the value corresponds to the number of sections in parallel on the output. X12 owner's manual (EN) version 1.0...
  • Page 74: Corrective Maintenance

    Coaxial loudspeaker (p.77) • HF diaphragm (p.78) For advanced maintenance, contact your L-Acoustics representative. Tools and consumables Before performing maintenance on this product, make sure all the tools listed are available. References are given for FACOM ® products in this table. Other manufacturers can be used.
  • Page 75 Corrective maintenance Disassembly and Reassembly procedures In order to operate, follow the order outlined here. Each assembly refers to the corresponding D/R procedure and the necessary repair kit. GRILL HF DIAPHRAGM G03175 COAXIAL SPEAKER G03169 X12 owner's manual (EN) version 1.0...
  • Page 76 Corrective maintenance D/R - Grill Tools • torque screwdriver • T25 Torx bit Repair kit G03169 - KR coaxial speaker X12 or G03175 - KR diaphragm X12 ×6 S100033 M5×25 Torx Exploded view For safety reasons, always use the new screws and spare parts provided in the KR.
  • Page 77 For safety reasons, always use the new screws and spare parts provided in the KR. Gradually tighten the screws following a star pattern. If the speaker gasket is damaged, remove and replace it. 5 N.m 5 mm What to do next Perform the Acoustical check (p.42) procedures. X12 owner's manual (EN) version 1.0...
  • Page 78 Use the 3 mm hex bit. 2. Remove the cover. 3. Carefully remove the diaphragm. 4. If there are shims on the dome, carefully remove them. Take note of how many and what kind of shims are present. X12 owner's manual (EN) version 1.0...
  • Page 79 Tighten the screws in the same order with the electric screwdriver. Use the 3 mm hex bit. Set the torque to 3.5 Nm. What to do next Perform the Acoustical check (p.42) procedures. X12 owner's manual (EN) version 1.0...
  • Page 80: Forbidden ConGurations

    Forbidden congurations Forbidden congurations Forbidden Authorized X12 owner's manual (EN) version 1.0...
  • Page 81 Forbidden congurations Forbidden Authorized X12 owner's manual (EN) version 1.0...
  • Page 82: SpeciCations

    X12 specications Description 2-way passive coaxial enclosure: 12'' LF + 3'' HF diaphragm, amplied by LA4X / LA8 / LA12X Usable bandwidth (-10 dB) 59 Hz - 20 kHz ([X12]) Maximum SPL 136 dB ([X12]) Nominal directivity (-6 dB) vertical: 90°...
  • Page 83 Specications X12 dimensions 430 mm / 16.9 in 375 mm / 14.8 in 471 mm / 18.5 in 500 mm / 19.7 in X12 owner's manual (EN) version 1.0...
  • Page 84 Pantone 426 C pure white RAL 9010 custom RAL code on special order IP55 Peak level at 1 m under half space conditions using pink noise with crest factor 4 (preset specied in brackets). X12 owner's manual (EN) version 1.0...
  • Page 85 Specications SB15m dimensions 520 mm / 20.5 in 580 mm / 22.8 in X12 owner's manual (EN) version 1.0...
  • Page 86 Rigging components steel with anti-corrosion coating Finish dark grey brown Pantone 426 C IP55 Peak level at 1 m under half space conditions using pink noise with crest factor 4 (preset specied in brackets). X12 owner's manual (EN) version 1.0...
  • Page 87 Specications SB18 dimensions 707 mm / 27.8 in 750 mm / 29.5 in X12 owner's manual (EN) version 1.0...
  • Page 88 Pantone 426 C pure white RAL 9010 custom RAL code on special order IP55 Peak level at 1 m under half space conditions using pink noise with crest factor 4 (preset specied in brackets). X12 owner's manual (EN) version 1.0...
  • Page 89 Specications SB18 IIi dimensions 701 mm / 27.6 in 701 mm / 27.6 in X12 owner's manual (EN) version 1.0...
  • Page 90 Finish dark grey brown Pantone 426 C IP55 Peak level at 1 m under half space conditions using pink noise with crest factor 4 (preset specied in brackets). X12 owner's manual (EN) version 1.0...
  • Page 91 Specications KS21 dimensions 764 mm / 30 in 602 mm / 23.7 in 752 mm / 29.6 in X12 owner's manual (EN) version 1.0...
  • Page 92 Pantone 426 C pure white RAL 9010 custom RAL code on special order IP55 Peak level at 1 m under half space conditions using pink noise with crest factor 4 (preset specied in brackets). X12 owner's manual (EN) version 1.0...
  • Page 93 Specications KS21i dimensions 752 mm / 29.6 in 602 mm / 23.7 in X12 owner's manual (EN) version 1.0...
  • Page 94 X-UL12 dimensions 601 mm / 23.7 in 200 mm / 7.9 in Ø M10 559 mm / 22 in 53 mm / 2.1 in 96 mm / 3.8 in X12 owner's manual (EN) version 1.0...
  • Page 95 Specications X-US1215 specications Description Short U-bracket for X12 and X15 HiQ Weight (net) 3 kg / 6.6 lb Material high grade steel with anti-corrosion coating X-US1215 dimensions 535 mm / 21.1 in 200 mm / 7.9 in Ø M10 493 mm / 19.4 in 53 mm / 2.1 in...
  • Page 96 1 × Ø12 mm shackle WLL 1 t Weight (net) 1.1 kg / 2.4 lb Material high grade steel with anti-corrosion coating X-BAR dimensions 83 mm / 3.3 in Ø 13 mm / 0.5 in 185 mm / 7.3 in X12 owner's manual (EN) version 1.0...
  • Page 97 1.5 kg / 3.3 lb Material high grade steel with anti-corrosion coating X-UTILT dimensions 300 mm / 11.8 in 88 mm / 3.5 in 65 mm / 2.6 in 200 mm / 7.9 in Ø M10 X12 owner's manual (EN) version 1.0...
  • Page 98 Pole mount socket: 8XTi/12XTi and X series Weight (net) 0.5 kg / 1 lb Material high grade steel with anti-corrosion coating EMBi dimensions 35 mm / 1.4 in 46 mm / 1.8 in 115.5 mm / 4.5 in X12 owner's manual (EN) version 1.0...
  • Page 99: Appendix: Recommendation For Speaker Cables

    8 Ω load 4 Ω load 2.7 Ω load Use the more detailed L-Acoustics calculation tool to evaluate cable length and gauge based on the type and number of enclosures connected. The calculation tool is available on our website: https://www.l-acoustics.com/en/installation/tools/...
  • Page 100 L-Acoustics 13 rue Levacher Cintrat - 91460 Marcoussis - France +33 1 69 63 69 63 - info@l-acoustics.com www.l-acoustics.com...

This manual is also suitable for:

Sb15mSb18Sb18 iiiKs21Ks21i

Table of Contents