Tx Port Settings - Victron energy SmartSolar MPPT 75/10 Manual

Solar charger
Table of Contents

Advertisement

Setting the dimming speed to 9, for example, slows down the dimming speed to 15 minutes (9 seconds for each percentage
point of dimming x 100 percentage points = 900 seconds = 15 minutes.
Make sure that the TX port function is set to "Light dimming" mode (as described in point
this chapter) and connect a VE.Direct TX digital output cable to the PWM dim input of your LED driver.
Mid-point shift
The time of midnight is estimated based on solar activity, and depends on your geographical location. Daylight saving times can
cause a further deviation between the "solar" and the "clock" midnight. The Mid-point shift function will compensate for these
differences. Use 0 to disable the shift (default).
The Mid-point shift setting is only relevant when your streetlight setting program uses "Midnight" as a
switching moment.
Calculation Example:
For calculation we use a day of 1440 minutes, where Sunset is at 19:00 (1140 minutes) and Sunrise is at 6:25 (385 minutes):
• The night duration in minutes is: 1440m
• The degree of shift = time of sunset
42 minutes.
Example configuration
The selections which have been made on above screen image results in this program:
• At sunset - the light will be switched on for a fixed time
• Dim level at sunset - at Full brightness (100%)
• Keep lights on during - the duration has been set to 1h 0m
• Dim level at end - at the end of one hour the brilliance will be reduced to half (50%)
Also:
• At sunrise - the lighting will be adjusted before sunrise
• Time before sunrise - at 1h 0m before sunrise, the following adjustment will be made:
• Dim level - full brilliance will be restored (100%)

5.2.4. TX port settings

The VE.Direct-TX port can be used to send a signal to an external device. For example to send a PWM signal to dim a streetlight.
Be aware that changing away from the default setting while a
to be removed and the load output algorithm has to be configured via the
[21]
instead.
To use the TX port, a
VE.Direct TX digital output cable
Page 24
MPPT solar charger manual
(min/day)
-1140m(time to sunset) + 385m
(minutes)
+ half the duration of night
is needed.
(time to sunrise)
= 685m
(minutes)
(minutes)
- length of day
= 1140m + 342m - 1440m =
jumper link [14]
is used, the jumper link will need
VictronConnect load output setting
Configuration and settings
1
at the beginning of

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents