12, 12 CO, 12 CO PN63

4.4 Climatic zones and performance data

Depending on which climatic zone the product is used in, the product performance differs depending on the climatic
ambient conditions.
Climatic zone
Unit
m³/min.
green
blue
red
The performance data given refer to a moderate climate valid for Europe, large parts of South-East Asia, North and South
Africa, parts of North and South America (climatic zone: blue).
For a dry and / or cool climate (climatic zone: green), the following factor applies:
Performance in climatic zone "blue" x approx. 1.2
For a hot and / or humid climate (tropics, climatic zone: red), the following factor applies:
Performance in climatic zone "blue" x approx. 0.7

4.4.1 Performance data

BEKOMAT
®
Max. compressor
performance
Max. refrigeration dryer
performance
Max. filter performance
Operating pressure
Ø discharge rate
Max. discharge rate (short-
term)*
* The peak volume can only be achieved if the device is correctly installed according to the installation and operation
manual. If in doubt, a venting line must be installed.
16 | 64
Max. compressor
performance
cfm
8.0
283
6.5
230
4.0
141
12
1 bar(g)
2 bar(g)
14.5 psi(g)
29.01 psi(g)
0.95 l/h
1.10 l/h
0.25 gal/h
0.29 gal/h
20 l/h
23 l/h
5.28 gal/h
6.07 gal/h
Original installation and operation manual
Max. dryer performance
m³/min.
cfm
16.0
565
13.0
459
8.0
283
12 CO
6.5 m³/min
230 cfm
13 m³/min
460 cfm
65 m³/min
2300 cfm
3 bar(g)
4 bar(g)
43.51 psi(g)
58.02 psi(g)
1.29 l/h
0.34 gal/h
27 l/h
7.13 gal/h
Max. filter performance
m³/min.
cfm
80.0
2825
65.0
2300
40.0
1413
12 CO PN63
5 bar(g)
≥ 6 bar(g)
72.52 psi(g)
87.02 psi(g)
1.43 l/h
0.37 gal/h
30 l/h
7.92 gal/h