Connection Of Potential Free Contact - Beko BEKOMAT 12 Original Installation And Operation Manual

Table of Contents

Advertisement

Original installation and operation manual

7.2.2 Connection of potential free contact

The BEKOMAT
has a potential-free contact on the power control board. A fault signal can be indicated at a remote
®
maintenance centre through this.
Illustration
6 mm (0.23")
60 mm (2.36")
5
6
4
7
I
Normally Open (NO)
Common (CO)
Normally Closed (NC)
PE
Schutzleiter (PE)
N
Neutralleiter (N)
L
Phase (L)
BEKOMAT
Description / explanation
1. Prepare the 2/3-wire cable of the potential-free
contact (depending on the application).
If the external TEST button is to be connected
in addition to the potential-free contact,
a 4/5-wire cable must be used for the
connection (depending on the application).
2. Take the dust protection pane [4] out.
3. Slide the components of the cable gland [5, 6, 7] over
the cable for potential-free contact [I] and insert the
cable into the top cover.
4. Connect the cable of the potential-free contact to the
power control board in accordance with the terminal
diagram.
12, 12 CO, 12 CO PN63
®