Technical data

min./max. operating pressure
min./max. temperature
Condensate inflow
Condensate outflow
Condensate
Housing
Weight (empty)
This product has been tested to the requirements of CAN/CSA-C22.2 No. 61010-1-12, third edition, inclu-
ding a later version of the same standard incorporating the same level of testing requirements.
6

Electrical data

Supply voltage
(see type plate)
Power consumption
Fusing
Recommended
cable-jacket diameter
Recommended
wire cross-section
BEKOMAT® 31U IF built-in F
0,8...16 bar (12...230 psi)
+1...+70 °C (+34...+158 °F)
G ½ (NPT ½) internal
max. screw-in depth 13,5 mm (½")
G ¼ Ø 8 ... 10 mm hose connector
oil-contaminated + oil-free
aluminium + plastic, glass fibre-reinforced
0.6 kg (1.3 lbs)
24 VDC ± 10 % from a power supply unit with safe (mains) separation
P < 2 W
device has an internal
self-resetting fuse 0.3 A
Ø 5.0...10 mm (0.20"...0.39")
0.25...1.5 mm² (AWG 16...24)
~ 50 mm (~ 1.97")
~ 8 mm (~ 0.31 inch)
IP 67