4. Set up Instruction

On/Off
Power on
Turn on
Turn off
(Restore to factory setting)
Power off
Note:
Network Joining
Never joined the network
Had joined the network
Function Key
Press and hold for 5 seconds
Press once
Sleeping Mode
The device is on and in the
network
Low Voltage Warning
Low Voltage
Insert batteries. (users may need a flat blade screwdriver to open);
Insert two sections of 3V CR2450 button batteries and close the battery cover.)
Press any function key till green and red indicator flashes once.
Press and hold the function key for 5 seconds till green indicator flashes for 20 times.
Remove Batteries.
1. Remove and insert the battery; the device memorizes previous on/off state by default.
2. On/off interval is suggested to be about 10 seconds to avoid the interference of capacitor
inductance and other energy storage components.
3. Press any function key and insert batteries at the same time; it will enter engineer testing mode.
Turn on the device to search the network.
The green indicator stays on for 5 seconds: success
The green indicator remains off: fail
Turn on the device to search the previous network.
The green indicator stays on for 5 seconds: success
The green indicator remains off: fail
Restore to factory setting / Turn off
The green indicator flashes for 20 times: success
The green indicator remains off: fail
The device is in the network: green indicator flashes once and sends a report
The device is not in the network: green indicator remains off
Sleeping period: Min Interval.
When the reportchange exceeds setting value or the state changes: send a data report according to
Min Interval.
2.4V
4