Download Print this page
Mars High Velocity 2 Series Manual

Mars High Velocity 2 Series Manual

Electric heated

Advertisement

HV2 Submittal Package
14716 S. BROADWAY, GARDENA, CA 90248 ● Ph: (310)532-1555 Fax: (310)-532-3030 ●
www.marsair.com
© Copyright Mars Air Systems, LLC 2014
HV2 Electric
Heated Series 2
High Velocity Series 2
Air Curtain
Submittal Package
Submitted by:
Mars Air Systems, LLC
14716 S. Broadway
Gardena, CA 90248
P.O.#
S.Q.
Company
Print Name
Signature
Date
Company Seal or Stamp
(Electronic Signature Preferred)
NOTE: MARS AIR SYSTEMS, LLC reserves the right to change specifications and product design without notice. Such revisions do not entitle the buyer to corresponding changes, improvements, additions, or replacements
for previously purchased equipment.
MARS AIR SYSTEMS, LLC
GARDENA, CA
USA

Advertisement

loading

Summary of Contents for Mars High Velocity 2 Series

  • Page 1 Company Seal or Stamp (Electronic Signature Preferred) NOTE: MARS AIR SYSTEMS, LLC reserves the right to change specifications and product design without notice. Such revisions do not entitle the buyer to corresponding changes, improvements, additions, or replacements for previously purchased equipment.
  • Page 2: Table Of Contents

    CSI Spec Reference Links NOTE: MARS AIR SYSTEMS, LLC reserves the right to change specifications and product design without notice. Such revisions do not entitle the buyer to corresponding changes, improvements, additions, or replacements for previously purchased equipment. MARS AIR SYSTEMS, LLC GARDENA, CA ●...
  • Page 4 WATTAGE CODE COLOR NOTE: MARS AIR SYSTEMS, LLC reserves the right to change specifications and product design without notice. Such revisions do not entitle the buyer to corresponding changes, improvements, additions, or replacements for previously purchased equipment. MARS AIR SYSTEMS, LLC GARDENA, CA ●...
  • Page 7: Copyright Mars Air Systems, Llc 2014

    99-277 – Thermostat, 24 Volt, Single Stage, R.W. 99-182 - Cover, Lockable, Clear NOTE: MARS AIR SYSTEMS, LLC reserves the right to change specifications and product design without notice. Such revisions do not entitle the buyer to corresponding changes, improvements, additions, or replacements for previously purchased equipment.
  • Page 8: Accessory Installation Supplement

    3. All wiring must be per local and NEC (National Electric Code) codes. 1. Mars door limit and magnetic reed switches are 4. Panels or controllers may be required. Refer to wiring available with NEMA 1, 4X and 7 ratings. Contact the diagram inside the control panel box.
  • Page 9 Document No: ACC-IOM Date: 04/13/2013 Bracket Installation 1. Side Extension Plates: For doorways wider than the air curtain, use combination of Side Extension Plates and Adjustable Mounting Brackets. (FIG. 5) FIG. 7 (WMI/WMH Shown) FIG. 5 (LPV SHOWN) 2. Adjustable Mounting Brackets: For installation of air curtain over drum-style roll-up door, use Extended Wall Mounting Brackets.
  • Page 10: Installation, Operation And Maintenance

    Improper Control up to 10’), High Velocity 2 Series (Environmental installation can result in electric shock, possible injury Separation up to 14’, Flying Insect Control up to 12’), and due to coming in contact with moving parts, as well as Extra Power 2 Series (Environmental up to 16’, Flying...
  • Page 11 Verify that all parts, components and accessories, and the correct quantities of each have been received. If any items are missing, report shortages to Mars Air Systems directly to arrange for obtaining the missing items. Again, verify quantities received against those on the Bill of Lading only, as multiple shipments may be involved.
  • Page 12 power or motor leads and the motor will rotate the START-UP opposite direction. Make sure all motors are turning in the same and proper direction. (FIG. 2) This product has been assembled and tested at the 4. Replace the air intake grille(s) or filter(s) once the factory prior to shipping.
  • Page 13 To clean the product, perform the following: a control panel or an On/Off switch, open the door to energize the product. 1. Verify the product has been disconnected from the J. If heated products are installed, reference Heated power source. Products Supplement.
  • Page 14 CAUTION DISCLAIMER The appliance is not to be used by persons (including Mars reserves the right to change specifications and children) with reduced physical, sensory, or mental product design without notice. Such revisions do not capabilities, or lack of experience and knowledge, unless...
  • Page 15 TROUBLESHOOTING MOTOR To determine if the motor is in good operating condition, compare measured motor resistance at the motor terminals to the values shown below. MARS MOTOR RESTANCE READINGS Single Phase Motors MOTOR WIRES OR TERMINAL (T) OHM READINGS HIGH SPEED (1750) MEDIUM SPEED (1650) LOW SPEED (1450) Applicable Black Motor Wire &...
  • Page 16: Warranty

    Mars is not responsible. The warranty does not cover damages caused by mishandling during transportation. The warranty is voided by removal or alteration of Mars...
  • Page 17: Heated Products Supplement

    Document No: HT-IOM Date: 04/09/2020 HEATED PRODUCTS SUPPLEMENT NOTE Before proceeding, refer to the units specific IOM Manual for safety, installation and start information. Verify proper voltage to the product per local and NEC codes. Ensure proper rotation for units with three phase motors.
  • Page 18 Steam and Hot Water Coil Heated Products The transition section(s) are shipped knocked down and are to be field assembled and installed per their Steam/Hot Water Coil (coil) heated products must supplemental instructions. (FIG. 6) (Exceptions are be mounted on the inside of the building. The coil(s) for WMI/H and BD series, fully assembled transitions are Low Profile, Standard, High Velocity, Extra Power and provided).
  • Page 19 Mars High Velocity Series 2-CSI-Spec Revised 10/15/2020 MARS AIR SYSTEMS, LLC SECTION 23 24 33.7 AIR CURTAINS Important Note: This specification contains hidden text appearing in red. To show or remove hidden text in MSWord, click the “File” tab or “Office” icon on the top-left corner, select “Options,” select “Display,”...
  • Page 20 Mars High Velocity Series 2-CSI-Spec Revised 10/15/2020 MARS AIR SYSTEMS, LLC Section 23 22 13- Steam and Condensate Piping: Steam heating piping to units. Section 26 05 00 – Equipment Wiring: Connections to building power distribution. REFERENCES ASTM A240 / A240M -10 – Standard Specification for Chromium and Chromium.
  • Page 21 Mars High Velocity Series 2-CSI-Spec Revised 10/15/2020 MARS AIR SYSTEMS, LLC Product data and certification letter indicating percentages by weight of post- consumer and pre-consumer recycled content for products having recycled content. Selection Samples: For each finish product specified, two complete sets of color chips representing manufacturer's full range of available colors and patterns.
  • Page 22 PART 2 PRODUCTS MANUFACTURER Acceptable Manufacturer: Mars Air Systems, LLC; 14716 South Broadway St., Gardena, CA 90248. Tel: (310) 532-1555 or (800) 421-1266. Fax: (310) 324-3030. Email: info@marsair.com. Web: www.marsair.com. Delete one of the following two paragraphs: coordinate with requirements of Division 1 section on product options and substitutions.
  • Page 23 Mars High Velocity Series 2-CSI-Spec Revised 10/15/2020 MARS AIR SYSTEMS, LLC Size: Unheated: 15-5/8 inches deep by 14 inches high (including discharge nozzle) by width of unit. Electric Heated: 21-3/8 inches deep by 14 inches high (including discharge nozzle) by width of unit.
  • Page 24 Mars High Velocity Series 2-CSI-Spec Revised 10/15/2020 MARS AIR SYSTEMS, LLC HV296-2: 96 Inch (2440 mm) Wide Units: 2447 feet/min (12.4 m/s) two 1HP motor/fan assemblies. HV2108-3: 108 Inch (2743 mm) Wide Units: 2745 feet/min (13.9 m/s) two 1HP motor/fan assemblies.
  • Page 25 Mars High Velocity Series 2-CSI-Spec Revised 10/15/2020 MARS AIR SYSTEMS, LLC NH2120-3: 120 Inch (3050 mm) Wide Units: 2678 feet/min (13.6 m/s) single 1HP motor/fan assembly. NH2144-3: 14 Inch (3660 mm) Wide Units: 2447 feet/min (12.4 m/s) single 1HP motor/fan assembly, Air Speed at Floor: Service entry doors require a minimum of 1600 fpm (8.13 m/s) at 3 feet...
  • Page 26 Mars High Velocity Series 2-CSI-Spec Revised 10/15/2020 MARS AIR SYSTEMS, LLC Gas Heaters: Provide field mounted indirect natural gas fired, power vented duct furnace, with aluminized steel heat exchanger and die-formed stainless steel insert burners; manifolds, orifices, flame sensor, and igniter easily removable as an assembly.
  • Page 27 Mars High Velocity Series 2-CSI-Spec Revised 10/15/2020 MARS AIR SYSTEMS, LLC Optional adaptive fan speed control based on existing field conditions. Field mounted outdoor temperature sensors required. Motor Control Panels for Electric Heated Units: Recommended for all three-phase units and single-phase units with combined motor capacities of more than 1HP whenever a door limit switch is used to automatically start and stop the air curtain.
  • Page 28 Mars High Velocity Series 2-CSI-Spec Revised 10/15/2020 MARS AIR SYSTEMS, LLC Pre-set and fully customizable programs Time delay (Passive & Adaptive) 24/7 timer Maintenance schedule alerts Status display showing date, time, temperature, and air curtain mode Multi-unit control capability English (IP) or Metric (SI) display readings...
  • Page 29 Mars High Velocity Series 2-CSI-Spec Revised 10/15/2020 MARS AIR SYSTEMS, LLC Door-Activated Limit switch(s): Provide, field installed 250-Volts, 20 amps limit switch to control air curtain(s) as follows; Automatic on/off control, activates air curtain when door is opened and turns off when door is closed. Provide limit switch for direct control one 1 HP or up to two 1/2 HP single phase motors without a separate control panel.
  • Page 30 Mars High Velocity Series 2-CSI-Spec Revised 10/15/2020 MARS AIR SYSTEMS, LLC Coordinate with electrical power as specified in Section 26 05 00. Install door limit switches and adjust for correct operation. Provide connection to piped services and utilities as specified in Section 22 10 00 and 23 21 00.
  • Page 31: Reference Links

    HV2 Series CSI spec (Word doc) NOTE: MARS AIR SYSTEMS, LLC reserves the right to change specifications and product design without notice. Such revisions do not entitle the buyer to corresponding changes, improvements, additions, or replacements for previously purchased equipment.