NOTE: MARS AIR SYSTEMS, LLC reserves the right to change specifications and product design without notice. Such revisions do not entitle the buyer to corresponding changes, improvements, additions, or replacements
Page 1
Company Seal or Stamp (Electronic Signature Preferred) NOTE: MARS AIR SYSTEMS, LLC reserves the right to change specifications and product design without notice. Such revisions do not entitle the buyer to corresponding changes, improvements, additions, or replacements for previously purchased equipment.
CSI Spec Reference Links NOTE: MARS AIR SYSTEMS, LLC reserves the right to change specifications and product design without notice. Such revisions do not entitle the buyer to corresponding changes, improvements, additions, or replacements for previously purchased equipment. MARS AIR SYSTEMS, LLC GARDENA, CA ●...
2 Motor Unit = 66 dBA, 3 Motor Unit = 67 dBA, 4 Motor Unit = 68dBA Furnace Only NOTE: MARS AIR SYSTEMS, LLC reserves the right to change specifications and product design without notice. Such revisions do not entitle the buyer to corresponding changes, improvements, additions, or replacements for previously purchased equipment.
Page 7
99-263 – Thermostat, 24 Volt, Digital, Single Stage., R.G.W.Y.B.O., Battery Power NOTE: MARS AIR SYSTEMS, LLC reserves the right to change specifications and product design without notice. Such revisions do not entitle the buyer to corresponding changes, improvements, additions, or replacements for previously purchased equipment.
3. All wiring must be per local and NEC (National Electric Code) codes. 1. Mars door limit and magnetic reed switches are 4. Panels or controllers may be required. Refer to wiring available with NEMA 1, 4X and 7 ratings. Contact the diagram inside the control panel box.
Page 9
Document No: ACC-IOM Date: 04/13/2013 Bracket Installation 1. Side Extension Plates: For doorways wider than the air curtain, use combination of Side Extension Plates and Adjustable Mounting Brackets. (FIG. 5) FIG. 7 (WMI/WMH Shown) FIG. 5 (LPV SHOWN) 2. Adjustable Mounting Brackets: For installation of air curtain over drum-style roll-up door, use Extended Wall Mounting Brackets.
Page 10
XFC-1 XF/XC SERIES Commercial/Light Commercial Unit Heaters STANDARD FEATURES OPTIONAL FEATURES • Standard or separated combustion all-in-one units • Stainless steel heat exchanger, burners, and/or flue collector • 20-gauge aluminized steel tubular heat exchanger • Two stage and various electronic modulation gas controls •...
Page 11
XF/XC SERIES DESCRIPTION ADDITIONAL VENTING FLEXIBILITY The Sterling “XF/XC” Series Convertible Venting Type Tubular The Sterling “XF/XC” unit heater is ETL certified in accordance with Gas-Fired Unit Heater offers a highly efficient, extremely durable categories I and III venting requirements. This certification allows units alternative to the traditional clam shell design.
Protect yourself and others by observing all safety information. Failure to comply with these instructions could result in personal injury and/or property damage. Retain these instructions for future reference. OVERVIEW GENERAL SAFETY INFORMATION Mars Air Curtains are designed to cover door Use this product only in openings, providing the manner intended by...
Page 13
Verify that all parts, components and accessories, and the correct quantities of each have been received. If any items are missing, report shortages to Mars Air Systems directly to arrange for obtaining the missing items. Again, verify quantities received against those on the Bill of Lading only, as multiple shipments may be FIG.
Page 14
D. Check all field wired components “if supplied” are wired correctly. E. Check that the inlet air supply and the discharge air supply are free of obstructions. F. Check that all air filter(s) and/or air intake grille(s) are in place and installed properly, as originally shipped. G.
Page 15
On average, under normal use DISCLAIMER conditions, the product should require a thorough cleaning once every six (6) months. Mars reserves the right to change specifications and product design without notice. Such revisions do not To clean the product, perform the following: entitle...
Document No: HT-IOM Date: 02/22/2023 HEATED PRODUCTS SUPPLEMENT NOTE Before proceeding, refer to the units specific IOM Manual for safety, installation and start information. Verify proper voltage to the product per local and NEC codes. Ensure proper rotation for units with three phase motors.
Page 17
Steam and Hot Water Coil Heated Products The transition section(s) are shipped knocked down and Steam/Hot Water Coil (coil) heated products must are to be field assembled and installed per their be mounted on the inside of the building. The coil(s) for supplemental instructions.
Page 18
TROUBLESHOOTING PROBLEM CAUSE SOLUTION NO AIR BLOWING - No power being supplied to the unit OUT OF DISCHARGE - Confirm power source / check if in on position from the electrical power source NOZZLE - Circuit breaker is tripped - Reset circuit breaker - Blown fuses on power supply - Replace fuses - Allow the motor to cool down;...
Page 19
TROUBLESHOOTING MOTOR To determine if the motor is in good operating condition, compare measured motor resistance at the motor terminals to the values shown below. MARS MOTOR RESISTANCE READINGS Single Phase Motors MOTOR WIRES OR TERMINAL (T) OHM READINGS HIGH SPEED (1750) MEDIUM SPEED (1650) LOW SPEED (1450)
Page 20
Mars’ warranty coverage, period, extent, and limitations apply to the product only. It does not apply Date Purchased: ____________________________ to labor. Mars warrants that the Mars product 1) is Dealer Purchased From: ______________________ free from defects in materials and workmanship, and 2) conforms to Mars’...
Page 21
Mars Wind Stopping 14-CSI-Spec Revised 4/21/2023 MARS AIR SYSTEMS, LLC SECTION 23 34 33 AIR CURTAINS Important Note: This specification contains hidden text appearing in red. To show or remove hidden text in MSWord, click the “File” tab or “Office” icon on the top-left corner, select “Options,” select “Display,”...
Page 22
Mars Wind Stopping 14-CSI-Spec Revised 4/21/2023 MARS AIR SYSTEMS, LLC Section 23 22 13- Steam and Condensate Piping: Steam heating piping to units. Section 26 05 00 – Equipment Wiring: Connections to building power distribution. REFERENCES ASTM A240 / A240M -10 – Standard Specification for Chromium and Chromium.
Mars Wind Stopping 14-CSI-Spec Revised 4/21/2023 MARS AIR SYSTEMS, LLC Selection Samples: For each finish product specified, two complete sets of color chips representing manufacturer's full range of available colors and patterns. Verification Samples: For each finish product specified, two samples, minimum size 6.25 inches (160 mm) square, representing actual product, color, and patterns.
Page 24
MARS AIR SYSTEMS, LLC PART 2 PRODUCTS MANUFACTURER Acceptable Manufacturer: Mars Air Systems, LLC; 14716 South Broadway St., Gardena, CA 90248. Tel: (310) 532-1555 or (800) 421-1266. Fax: (310) 324-3030. Email: info@marsair.com. Web: www.marsair.com. Delete one of the following two paragraphs: coordinate with requirements of Division 1 section on product options and substitutions.
Page 25
Mars Wind Stopping 14-CSI-Spec Revised 4/21/2023 MARS AIR SYSTEMS, LLC Material: Provide 10-, 12-, and 14-gauge electro or hot dipped galvanized steel sheet housing conforming to ASTM A 591 and/or ASTM A 653. Provide type 304 stainless steel housing with brushed finish. ASTM A 240/A 240M.
Page 26
Mars Wind Stopping 14-CSI-Spec Revised 4/21/2023 MARS AIR SYSTEMS, LLC Temperature limit controller. Heating Coils: UL approved. Factory mounted on the intake side of the air curtain cabinet. Steam Heaters: Provide finned tube steam coils for field mounting on air intake side of the air curtain cabinet with opposite end connections.
Page 27
Mars Wind Stopping 14-CSI-Spec Revised 4/21/2023 MARS AIR SYSTEMS, LLC Motor Control Panels for Unheated Units: Recommended for units whenever a door limit switch is used to automatically start and stop the air curtain. Provide motor control panel as follows: Mounting: Shipped loose to be remote mounted.
Page 28
Mars Wind Stopping 14-CSI-Spec Revised 4/21/2023 MARS AIR SYSTEMS, LLC Operation for Unheated Units: Automatic on/off control, on when door is opened, off when door is closed. Operation for Gas Heated Units: Automatic on when door is opened, off after time delay period (60 seconds) after door is closed.
Page 29
Mars Wind Stopping 14-CSI-Spec Revised 4/21/2023 MARS AIR SYSTEMS, LLC Check heated air curtain performance on a calm day by measuring air temperature 6 inches off the floor. Optimal reading is halfway between the temperature inside and outside the building.
Wind Stopping 14 Series CSI spec (Word doc) NOTE: MARS AIR SYSTEMS, LLC reserves the right to change specifications and product design without notice. Such revisions do not entitle the buyer to corresponding changes, improvements, additions, or replacements for previously purchased equipment.
Need help?
Do you have a question about the WMI Series and is the answer not in the manual?
Questions and answers