Mars Phantom 10 Series Installation, Operation And Maintenance Manual

Mars Phantom 10 Series Installation, Operation And Maintenance Manual

Commercial, submittal package

Advertisement

 
 
PH10 Submittal Package 
PH10 Unheated Series
P.O.#
S.Q.
Company
Print Name
Signature
Date
(Electronic Signature Preferred)
NOTE:  MARS  AIR  SYSTEMS,  LLC  reserves  the  right  to  change  specifications  and  product  design  without  notice.  Such  revisions  do  not  entitle  the  buyer  to  corresponding  changes,  improvements,  additions  or 
replacements for previously purchased equipment. 
14716 S. BROADWAY, GARDENA, CA 90248 ● Ph: (310)532-1555 Fax: (310)-532-3030 ●
Phantom 10 Series
Commercial Air Curtain
Submittal Package
Submitted by:
Mars Air Systems, LLC
14716 S. Broadway
Gardena, CA 90248
MARS AIR SYSTEMS, LLC 
GARDENA, CA 
● 
© Copyright Mars Air Systems, LLC 2014
Company Seal or Stamp
USA 
● 
 
www.marsair.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Phantom 10 Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Mars Phantom 10 Series

  • Page 1 Date Company Seal or Stamp (Electronic Signature Preferred) NOTE:  MARS  AIR  SYSTEMS,  LLC  reserves  the  right  to  change  specifications  and  product  design  without  notice.  Such  revisions  do  not  entitle  the  buyer  to  corresponding  changes,  improvements,  additions  or  replacements for previously purchased equipment.  MARS AIR SYSTEMS, LLC  GARDENA, CA ...
  • Page 2 CSI Spec Reference Links NOTE: MARS AIR SYSTEMS, LLC reserves the right to change specifications and product design without notice. Such revisions do not entitle the buyer to corresponding changes, improvements, additions or replacements for previously purchased equipment. MARS AIR SYSTEMS, LLC GARDENA, CA ●...
  • Page 4 NOTE: MARS AIR SYSTEMS, LLC reserves the right to change specifications and product design without notice. Such revisions do not entitle the buyer to corresponding changes, improvements, additions or replacements for previously purchased equipment.
  • Page 6 Door Limit and Magnetic Reed Switches Electric Code) codes. 4. Panels or controllers may be required. Refer to wiring 1. Mars door limit and magnetic reed switches are diagram inside the control panel box. available with NEMA 1, 4X and 7 ratings. Contact the factory for additional ratings and details.
  • Page 7 Bracket Installation 1. Side Extension Plates: For doorways wider than the air curtain, use combination of Side Extension Plates and Adjustable Mounting Brackets. (FIG. 5) FIG. 7 (WMI/WMH Shown) FIG. 5 (LPV Shown) 2. Adjustable Mounting Brackets: For installation of air curtain over drum-style roll-up door, use Extended Wall Mounting Brackets.
  • Page 8: General Safety Information

    Protect yourself and others by observing all safety information. Failure to comply with these instructions could result in personal injury and/or property damage. Retain these instructions for future reference. OVERVIEW understanding these Mars Air Curtains instructions are designed to and should be cover door...
  • Page 9: Receiving And Inspection

    Verify that all parts, components and accessories, and FIG. 1 the correct quantities of each have been received. If any items are missing, report shortages to Mars Air Systems directly to arrange for obtaining the missing items. Again, verify quantities received against those on the Bill of Lading only, as multiple shipments may be involved.
  • Page 10 3. All 3 phase motors are bi-directional, which means they can rotate in either direction. Follow directional WARNING arrows on the blower wheel housings for proper rotation. If the motor is rotating incorrectly, switch two The following items must all be completed by a qualified of the 3 phase power or motor leads and the motor will installer and checked off when completed rotate the opposite direction.
  • Page 11: Maintenance

    Failure to do so will not only lower operational efficiency and performance, but Mars reserves the right to change specifications and also reduce the useful life of the product. The time product design without notice. Such revisions do not...
  • Page 12: Troubleshooting

    TROUBLESHOOTING PROBLEM CAUSE SOLUTION NO AIR BLOWING - No power being supplied to the unit OUT OF DISCHARGE - Confirm power source / check if in on position from the electrical power source NOZZLE - Circuit breaker is tripped - Reset circuit breaker - Blown fuses on power supply - Replace fuses - Allow the motor to cool down;...
  • Page 13: Warranty

    (including lost profits and savings), even if Mars, its suppliers, or its reseller is informed of their possibility. The warranty does not cover repair or exchange of Mars product resulting from misuse, accident, modification, unsuitable...
  • Page 14 Document No: PH10-CSI Date: 031016 SECTION 15831 AIR CURTAINS PART 1 GENERAL SECTION INCLUDES Air curtains for pedestrian entrances. Air curtains for vehicular entrances. Air curtains for large loading dock doors. RELATED SECTIONS Section 05500 - Metal Fabrications: Concealed steel support members. Section 06100 - Rough Carpentry.
  • Page 15 Applications. ASTM A591 / A591M -98 – Standard Specification for Steel Sheet, Electrolytic Zinc- Coated, for Light Coating Weight (Mass) Application (Withdrawn in 2005, replaced by A879/A879M). ASTM A879 / A879M -06 – Standard Specification for Steel Sheet, Zinc Coated by the Electrolytic Process for Application Requiring Designation of the Coating Mass on Each Surface.
  • Page 16: Quality Assurance

    Product Data: Manufacturer's data sheets on each product to be used, including: Preparation instructions and recommendations. Storage and handling requirements and recommendations. Installation methods. Shop Drawings: Include plans, elevations, sections, and details, indicating dimensions, tolerances, materials, fasteners, hardware, finish, piping, electrical wiring diagrams, options, and accessories.
  • Page 17 Requests for substitutions will be considered in accordance with provisions of Section 01600. ** NOTE TO SPECIFIER ** Phantom 10 Series air curtains are available for openings 36 inches to 144 inches wide. Recommended installation heights for environmental separation up to 12’ and for flying insect control is up to 10. Phantom Series air curtains for temperature control applications are typically effective to resist wind loads up to 12 mph.
  • Page 18 ceiling without intermediate support. Units longer than 72” are two units tandem mounted next to each other. Size: Unheated: 26 inches deep by 15-1/2 inches high by width of unit. Electric Heated: 26 inches deep by 15-1/2 inches high by width of unit. Hot Water/Steam Heated: 26 inches deep by 15-1/2 inches high by width of unit plus 10 inches for manifolds.
  • Page 19 Type: Fixed air intake grille. Filter: Aluminum mesh, 1/4 inch (6.4 mm), washable. Type: Filter Only as follows: Filter: Flat bank 1 inch, disposable. Filter: Aluminum mesh, 1/4 inch (6.4 mm), washable. Speed: 2550 cu ft/min (1200 L/s), minimum, per motor/fan assembly. Sound Pressure Level At 10 feet (3 m) From Nozzle: Single Motor/Fan Units: 66 dBA.
  • Page 20 Motor Control Panel is included for all electric heated units. Thermostat is provided for field installation. Provide motor control panels as follows: Mounting: Factory mounted on right hand side of air curtain housing. Mounting: Factory mounted on left hand side of air curtain housing. Electrical components UL/CUL listed.
  • Page 21 Install air curtains in accordance with approved shop drawings and manufacturer's printed installation instructions. Install air curtains plumb, level, square, true to line, and weathertight, without warp or rack. Anchor air curtains securely in place to supports. Install sheet metal flashing as specified in Section 07620. Install joint sealants as specified in Section 07920.
  • Page 22: Reference Links

    CSI Spec Word Doc Download NOTE: MARS AIR SYSTEMS, LLC reserves the right to change specifications and product design without notice. Such revisions do not entitle the buyer to corresponding changes, improvements, additions or replacements for previously purchased equipment.

Table of Contents