Mars Extra Power 2 Series Manual

Industrial air curtain submittal package
Hide thumbs Also See for Extra Power 2 Series:

Advertisement

EP2 Submittal Package
EP2 Hot Water/Steam
Project Name
P.O.#
S.Q.
Company
Print Name
Signature
Date
(Electronic Signature Preferred)
NOTE: Mars Air Systems, LLC reserves the right to change specifications and product design without notice. Such revisions do not entitle the buyer to corresponding changes, improvements, additions, or replacements for
previously purchased equipment.
Heated Series
Extra Power Series 2
Industrial Air Curtain
Submittal Package
Submitted by:
Mars Air Systems, LLC
14716 S. Broadway
Gardena, CA 90248
MARS AIR SYSTEMS, LLC
14716 S. BROADWAY, GARDENA, CA 90248 ● Ph: (310)532-1555 Fax: (310)-532-3030 ●
GARDENA, CA
USA
www.marsair.com
© Copyright Mars Air Systems, LLC 2014
Company Seal or Stamp

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Extra Power 2 Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Mars Extra Power 2 Series

  • Page 1 Company Seal or Stamp (Electronic Signature Preferred) NOTE: Mars Air Systems, LLC reserves the right to change specifications and product design without notice. Such revisions do not entitle the buyer to corresponding changes, improvements, additions, or replacements for previously purchased equipment.
  • Page 2 CSI Spec Reference Links NOTE: Mars Air Systems, LLC reserves the right to change specifications and product design without notice. Such revisions do not entitle the buyer to corresponding changes, improvements, additions, or replacements for previously purchased equipment. MARS AIR SYSTEMS, LLC GARDENA, CA ●...
  • Page 3 2850 with a 17% reduction in performance. NOTE: Mars Air Systems, LLC reserves the right to change specifications and product design without notice. Such revisions do not entitle the buyer to corresponding changes, improvements, additions, or replacements for previously purchased equipment.
  • Page 4 1 Motor Unit = 76 dBA, 2 Motor Unit = 79 dBA, 3 Motor Unit = 81 dBA NOTE: Mars Air Systems, LLC reserves the right to change specifications and product design without notice. Such revisions do not entitle the buyer to corresponding changes, improvements, additions, or replacements for previously purchased equipment.
  • Page 5 Thank you for the above purchase order. The MARS EP2 series air curtains are specifically designed for manufacturing facilities with openings from 12 to 16 feet high. The decibel reading for the EP2 series is high due to the 2 pole motor design.
  • Page 7 Single Pole, R.G.W. 99-182 - Cover, Lockable, Clear NOTE: MARS AIR SYSTEMS, LLC reserves the right to change specifications and product design without notice. Such revisions do not entitle the buyer to corresponding changes, improvements, additions, or replacements for previously purchased equipment.
  • Page 8 3. All wiring must be per local and NEC (National Electric Code) codes. 1. Mars door limit and magnetic reed switches are 4. Panels or controllers may be required. Refer to wiring available with NEMA 1, 4X and 7 ratings. Contact the diagram inside the control panel box.
  • Page 9 Document No: ACC-IOM Date: 04/13/2013 Bracket Installation 1. Side Extension Plates: For doorways wider than the air curtain, use combination of Side Extension Plates and Adjustable Mounting Brackets. (FIG. 5) FIG. 7 (WMI/WMH Shown) FIG. 5 (LPV SHOWN) 2. Adjustable Mounting Brackets: For installation of air curtain over drum-style roll-up door, use Extended Wall Mounting Brackets.
  • Page 10 The motors used in the B. Installation work or electrical wiring must be done by Standard 2, High Velocity 2 and Extra Power 2 Series are qualified person(s) in accordance with all applicable 1/2HP, 1HP and 3HP, respectively. The ETL Sanitation codes and standards, including fire-rated construction.
  • Page 11: Receiving And Inspection

    Verify that all parts, components and accessories, and the correct quantities of each have been received. If any items are missing, report shortages to Mars Air Systems directly to arrange for obtaining the missing items. Again, verify quantities received against those on the Bill of Lading only, as multiple shipments may be involved.
  • Page 12 4. power or motor leads and the motor will rotate the WARNING opposite direction. Make sure all motors are The following items must all be completed by a qualified turning in the same and proper direction. (FIG. 2) installer and checked off when completed 5.
  • Page 13: Maintenance

    DISCLAIMER exterior components of the housing. Mars reserves the right to change specifications and 3. To access the interior of the product, remove the air product design without notice. Such revisions do not intake grille and/or air intake filter.
  • Page 14 Document No: HT-IOM Date: 10/20/2023 HEATED PRODUCTS SUPPLEMENT NOTE Before proceeding, refer to the unit’s specific IOM Manual for safety, installation, and startup information. Verify proper voltage to the product per local and NEC codes. Ensure proper rotation for units with three phase motors.
  • Page 15 Hot Water and Steam Heated Products The transition section(s) are shipped knocked down and are to be field assembled and installed per their Hot water and steam heated products are certified only supplemental instructions (FIG. 6). Exceptions are the for indoor use. Low Profile 2, Standard 2, High Velocity Wind Stopping (WMI, WMH) and WindGuard (BD) series, 2, Extra Power 2, and Phantom series units are shipped which are shipped with fully assembled transitions.
  • Page 16: Troubleshooting

    TROUBLESHOOTING PROBLEM CAUSE SOLUTION NO AIR BLOWING - No power being supplied to the unit OUT OF DISCHARGE - Confirm power source / check if in on position from the electrical power source NOZZLE - Circuit breaker is tripped - Reset circuit breaker - Blown fuses on power supply - Replace fuses - Allow the motor to cool down;...
  • Page 17: Troubleshooting Motor

    TROUBLESHOOTING MOTOR To determine if the motor is in good operating condition, compare measured motor resistance at the motor terminals to the values shown below. MARS MOTOR RESISTANCE READINGS Single Phase Motors MOTOR WIRES OR TERMINAL (T) OHM READINGS HIGH SPEED (1750) MEDIUM SPEED (1650) LOW SPEED (1450)
  • Page 18: Warranty

    Mars’ warranty coverage, period, extent, and limitations apply to the product only. It does not apply Date Purchased: ____________________________ to labor. Mars warrants that the Mars product 1) is Dealer Purchased From: ______________________ free from defects in materials and workmanship, and 2) conforms to Mars’...
  • Page 19 Mars Extra Power Series 2-CSI-Spec Revised 2/3/2021 MARS AIR SYSTEMS, LLC SECTION 23 34 33 AIR CURTAINS Important Note: This specification contains hidden text appearing in red. To show or remove hidden text in MSWord, click the “File” tab or “Office” icon on the top-left corner, select “Options,” select “Display,”...
  • Page 20 Mars Extra Power Series 2-CSI-Spec Revised 2/3/2021 MARS AIR SYSTEMS, LLC Section 23 22 13- Steam and Condensate Piping: Steam heating piping to units. Section 26 05 00 – Equipment Wiring: Connections to building power distribution. REFERENCES ASTM A240 / A240M -10 – Standard Specification for Chromium and Chromium.
  • Page 21: Quality Assurance

    Mars Extra Power Series 2-CSI-Spec Revised 2/3/2021 MARS AIR SYSTEMS, LLC Selection Samples: For each finish product specified, two complete sets of color chips representing manufacturer's full range of available colors and patterns. Verification Samples: For each finish product specified, two samples, minimum size 6.25 inches (160 mm) square, representing actual product, color, and patterns.
  • Page 22 MARS AIR SYSTEMS, LLC PART 2 PRODUCTS MANUFACTURER Acceptable Manufacturer: Mars Air Systems, LLC; 14716 South Broadway St., Gardena, CA 90248. Tel: (310) 532-1555 or (800) 421-1266. Fax: (310) 324-3030. Email: info@marsair.com. Web: www.marsair.com._ Delete one of the following two paragraphs: coordinate with requirements of Division 1 section on product options and substitutions.
  • Page 23 Mars Extra Power Series 2-CSI-Spec Revised 2/3/2021 MARS AIR SYSTEMS, LLC Hot Water/Steam Heated: 21 3/8 inches deep by 14 inches high (including discharge nozzle) by width of unit plus 10 inches for manifolds. Indirect Fired Gas Heated: 68 1/8 inches deep by 34 inches high (including discharge nozzle) by width of unit.
  • Page 24 Mars Extra Power Series 2-CSI-Spec Revised 2/3/2021 MARS AIR SYSTEMS, LLC Filter: Aluminum mesh, 1/4 inch (6.4 mm), washable. Speed: 4800 cu ft/min (2265 L/s), minimum, per motor/fan assembly. Sound Pressure Level At 10 feet (3 m) From Nozzle: Two Motor/Fan Units: 79 dBA.
  • Page 25 Mars Extra Power Series 2-CSI-Spec Revised 2/3/2021 MARS AIR SYSTEMS, LLC Output: Air curtain manufacturer's standard. Complies with: Canadian Standards Association (CSA) labeled for US and Canadian application. ANSI Z223/NFPA 54 National Fuel Gas Code. CAN/CGA B149.1 Installation Codes for Natural Gas Burning Appliances and Equipment.
  • Page 26 Mars Extra Power Series 2-CSI-Spec Revised 2/3/2021 MARS AIR SYSTEMS, LLC Control Panel: Includes increased transformer for power venter(s) with integrated 24-Volt thermostat with furnace and motor controls. Thermostat: Wall-mounted, 24-Volt operation, with heater on/off selection Mounting: Factory mounted on right hand side of air curtain housing.
  • Page 27 Mars Extra Power Series 2-CSI-Spec Revised 2/3/2021 MARS AIR SYSTEMS, LLC Anchor air curtains securely in place to supports. Coordinate with sheet metal flashing as specified in Section 07 62 00. Install joint sealants as specified in Section 07 92 00.
  • Page 28 EP2 Series CSI spec (Word doc) NOTE: Mars Air Systems, LLC reserves the right to change specifications and product design without notice. Such revisions do not entitle the buyer to corresponding changes, improvements, additions, or replacements for previously purchased equipment.