LOW PROFILE (LPV2) VARIABLE SPEED AND LOW PROFILE
(LPN2) ETL SANITATION CERTIFIED COMMERCIAL SERIES
Please read and save these instructions. Read carefully before attempting to assemble, install, operate, or maintain
the product described. Protect yourself and others by observing all safety information. Failure to comply with these
instructions could result in personal injury and/or property damage. Retain these instructions for future reference.

OVERVIEW

Mars Air Curtains are
designed
to
cover
door
openings,
providing
both
temperature
control/environmental
separation and flying
insect control, when
the building's doors
are opened. Typical
heights
are: LoPro Series; LPV2 (Variable Speed) models
(Environmental up to 8'), LPN2 (ETL Sanitation for
Customer Entrances) models (Flying Insect Control up to
7') and LPN2-F (ETL Sanitation for Counter Top/Pass
Through Windows) models (Flying Insect Control up to 4'
from Counter Top) All ETL Sanitation Certified Models
should be mounted at the Flying Insect Control heights
referenced above. The units are typically wall mounted
horizontally above the door opening. They can also be
suspended from the ceiling. The units are ETL Listed,
Canada and US, for either an inside or outside mount and
ETL Sanitation Certified. Heated units must be mounted
on the inside or the protected side of the opening. The
motors used in all LoPro Series are 1/6HP.
WARNING
When servicing the product, motor may be hot enough
to cause pain or injury. Allow motor to cool before
servicing.
The LoPro Series come standard with a stamped air
intake screen(s). The LPV2 models can be configured
with an aluminum mesh filter(s) as an option. The LPN2
models 25" and all LPN-F models come standard with an
aluminum mesh air intake filter(s) in conjunction with the
punched air intake screen(s).
Installation, Operation and Maintenance Manual
of these instructions and should be aware of general
safety precautions. Improper installation can result in
electric shock, possible injury due to coming in contact
with moving parts, as well as other potential hazards.
WARNING
To reduce the risk of fire, electric shock, or injury to
persons, observe the following.
A. Always disconnect, lock and tag power source before
installing or servicing product.
B. Installation work or electrical wiring must be done by
qualified person(s) in accordance with all applicable
codes and standards, including fire-rated construction.
C. The combustion airflow needed for safe operation of
fuel burning equipment in the area may be affected by
the product's operation. Follow the heating equipment
manufacturer's guideline and safety standards, such as
those published by the National Fire Protection Agency
(NFPA), the American Society of Heating, Refrigeration
and Air Conditioning Engineers (ASHRAE) and local
code authorities.
D. When cutting or drilling into a wall or ceiling, be careful
not to damage electrical wiring and other hidden
utilities.
Document No: LP2-IOM
Date: 08/21/20
GENERAL
SAFETY
INFORMATION
Use this product only in
the manner intended
by the manufacturer. If
you
have
any
questions, contact the
manufacturer.
Only
qualified
personnel
should
install
this
product.
Installing
personnel should have
a clear understanding

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the LPV2 Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Mars LPV2 Series

  • Page 1 Protect yourself and others by observing all safety information. Failure to comply with these instructions could result in personal injury and/or property damage. Retain these instructions for future reference. OVERVIEW GENERAL SAFETY INFORMATION Mars Air Curtains are Use this product only in designed cover the manner intended door openings, by the manufacturer.
  • Page 2 Verify that all parts, components and accessories, and the correct quantities of each have been received. If any FIG. 1 items are missing, report shortages to Mars Air Systems directly to arrange for obtaining the missing items. Again, verify quantities received against those on the Bill of Lading only, as multiple shipments may be involved.
  • Page 3 NOTE 6. Use four (4) threaded rods for overhead installation or For accessory installation, reference Accessory four (4) threaded bolts for wall installation. All hardware Installation Supplement. is field provided by others. (FIG. 3) For heated products, reference Heated Products Supplement.
  • Page 4 Air curtain must be mounted on the warm side for optimal A. Maintenance is to be performed only by qualified performance. LPV2 series with variable speed switch is personnel who are familiar with local codes and strongly recommended to control the air curtain air flow regulations and are experienced with this type of velocity at the floor level.
  • Page 5 TROUBLESHOOTING PROBLEM CAUSE SOLUTION NO AIR BLOWING - No power being supplied to the unit OUT OF DISCHARGE - Confirm power source / check if in on position from the electrical power source NOZZLE - Circuit breaker is tripped - Reset circuit breaker - Blown fuses on power supply - Replace fuses - Allow the motor to cool down;...
  • Page 6 TROUBLESHOOTING MOTOR To determine if the motor is in good operating condition, compare measured motor resistance at the motor terminals to the values shown below. MARS MOTOR RESISTANCE READINGS Single Phase Motors MOTOR WIRES OR TERMINAL (T) OHM READINGS HIGH SPEED (1750) MEDIUM SPEED (1650) LOW SPEED (1450) Applicable Black Motor Wire &...
  • Page 7 Mars’ warranty coverage, period, extent, and limitations apply to the product only. It does not apply Date Purchased: ____________________________ to labor. Mars warrants that the Mars product 1) is Dealer Purchased From: ______________________ free from defects in materials and workmanship, and 2) conforms to Mars’...

This manual is also suitable for:

Lpn2 seriesLpn2-fLpn236-1ud-ob

Table of Contents