Mars QuietPro 10 Series Manual

Mars QuietPro 10 Series Manual

Electric heated commercial air curtain

Advertisement

QP10 Submittal Package
QP10 Electric Heated
Project Name
P.O.#
S.Q.
Company
Print Name
Signature
Date
(Electronic Signature Preferred)
NOTE: MARS AIR SYSTEMS, LLC reserves the right to change specifications and product design without notice. Such revisions do not entitle the buyer to corresponding changes, improvements, additions, or replacements
for previously purchased equipment.
14716 S. BROADWAY, GARDENA, CA 90248 ● Ph: (310)532-1555 Fax: (310)-532-3030 ●
Series
QuietPro 10 Series
Commercial Air Curtain
Submittal Package
Submitted by:
Mars Air Systems, LLC
14716 S. Broadway
Gardena, CA 90248
MARS AIR SYSTEMS, LLC
GARDENA, CA
© Copyright Mars Air Systems, LLC 2014
Company Seal or Stamp
USA
www.marsair.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the QuietPro 10 Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Mars QuietPro 10 Series

  • Page 1 Company Seal or Stamp (Electronic Signature Preferred) NOTE: MARS AIR SYSTEMS, LLC reserves the right to change specifications and product design without notice. Such revisions do not entitle the buyer to corresponding changes, improvements, additions, or replacements for previously purchased equipment.
  • Page 2: Table Of Contents

    CSI Spec Reference Links NOTE: MARS AIR SYSTEMS, LLC reserves the right to change specifications and product design without notice. Such revisions do not entitle the buyer to corresponding changes, improvements, additions, or replacements for previously purchased equipment. MARS AIR SYSTEMS, LLC GARDENA, CA ●...
  • Page 3 Note: above data is for 60 Hz at 1725 RPM. For 50 Hz, RPM is 1425 with a 17% reduction in performance. NOTE: Mars Air Systems, LLC reserves the right to change specifications and product design without notice. Such revisions do not entitle the buyer to corresponding changes, improvements, additions, or replacements for previously purchased equipment.
  • Page 4 1 Motor Unit = 53 dBA, 2 Motor Unit = 55 dBA, 3 Motor Unit = 57 dBA, 4 Motor Unit = 59 dBA NOTE: Mars Air Systems, LLC reserves the right to change specifications and product design without notice. Such revisions do not entitle the buyer to corresponding changes, improvements, additions, or replacements for previously purchased equipment.
  • Page 7 99-263 – Thermostat, 24 Volt, Digital, Single Stage., R.G.W.Y.B.O., Battery Power NOTE: MARS AIR SYSTEMS, LLC reserves the right to change specifications and product design without notice. Such revisions do not entitle the buyer to corresponding changes, improvements, additions, or replacements for previously purchased equipment.
  • Page 8: Accessory Installation Supplement

    3. All wiring must be per local and NEC (National Electric Code) codes. 1. Mars door limit and magnetic reed switches are 4. Panels or controllers may be required. Refer to wiring available with NEMA 1, 4X and 7 ratings. Contact the diagram inside the control panel box.
  • Page 9 Document No: ACC-IOM Date: 04/13/2013 Bracket Installation 1. Side Extension Plates: For doorways wider than the air curtain, use combination of Side Extension Plates and Adjustable Mounting Brackets. (FIG. 5) FIG. 7 (WMI/WMH Shown) FIG. 5 (LPV SHOWN) 2. Adjustable Mounting Brackets: For installation of air curtain over drum-style roll-up door, use Extended Wall Mounting Brackets.
  • Page 10: Installation, Operation And Maintenance

    Protect yourself and others by observing all safety information. Failure to comply with these instructions could result in personal injury and/or property damage. Retain these instructions for future reference. OVERVIEW GENERAL SAFETY INFORMATION Mars Air Curtains are designed to cover door Use this product only in openings, providing the manner intended by...
  • Page 11 Verify that all parts, components and accessories, and the correct quantities of each have been received. If any items are missing, report shortages to Mars Air Systems directly to arrange for obtaining the missing items. Again, verify quantities received against those on the Bill of Lading only, as multiple shipments may be involved.
  • Page 12 10-15° towards the outside, or the wind load. (FIG. 4) POWER Typical Door Limit PANEL Switch Installation for Split Sliding Doors MARS Typical Door Limit Switch Installation for Commercial Swing Doors CONTROL PANEL Typical Door Limit Switch Installation for...
  • Page 13 Mars reserves the right to change specifications and 3. To access the interior of the product, remove the air product design without notice. Such revisions do not intake grille and/or air intake filter.
  • Page 14: Heated Products Supplement

    Document No: HT-IOM Date: 10/20/2023 HEATED PRODUCTS SUPPLEMENT NOTE Before proceeding, refer to the unit’s specific IOM Manual for safety, installation, and startup information. Verify proper voltage to the product per local and NEC codes. Ensure proper rotation for units with three phase motors.
  • Page 15 Hot Water and Steam Heated Products Hot water and steam heated products are certified only for indoor use. Low Profile 2, Standard 2, High Velocity 2, Extra Power 2, and Phantom series units are shipped with coils mounted in the interior of the unit. Wind Stopping and WindGuard units are shipped with coils factory mounted to the exterior of the unit.
  • Page 16 TROUBLESHOOTING PROBLEM CAUSE SOLUTION NO AIR BLOWING - No power being supplied to the unit OUT OF DISCHARGE - Confirm power source / check if in on position from the electrical power source NOZZLE - Circuit breaker is tripped - Reset circuit breaker - Blown fuses on power supply - Replace fuses - Allow the motor to cool down;...
  • Page 17 TROUBLESHOOTING MOTOR To determine if the motor is in good operating condition, compare measured motor resistance at the motor terminals to the values shown below. MARS MOTOR RESISTANCE READINGS Single Phase Motors MOTOR WIRES OR TERMINAL (T) OHM READINGS HIGH SPEED (1750) MEDIUM SPEED (1650) LOW SPEED (1450)
  • Page 18 Mars’ warranty coverage, period, extent, and limitations apply to the product only. It does not apply Date Purchased: ____________________________ to labor. Mars warrants that the Mars product 1) is Dealer Purchased From: ______________________ free from defects in materials and workmanship, and 2) conforms to Mars’...
  • Page 19 Mars QuietPro 10-CSI-Spec Revised 4/27/2023 MARS AIR SYSTEMS, LLC SECTION 23 34 33 AIR CURTAINS Important Note: This specification contains hidden text appearing in red. To show or remove hidden text in MSWord, click the “File” tab or “Office” icon on the top-left corner, select “Options,” select “Display,”...
  • Page 20 Mars QuietPro 10-CSI-Spec Revised 4/27/2023 MARS AIR SYSTEMS, LLC Section 26 05 00 – Equipment Wiring: Connections to building power distribution. REFERENCES ASTM A240 / A240M -10 – Standard Specification for Chromium and Chromium. ASTM A591 / A591M -98 – Standard Specification for Steel Sheet, Electrolytic Zinc- Coated, for Light Coating Weight (Mass) Application (Withdrawn in 2005, replaced by A879/A879M).
  • Page 21: Troubleshooting Guide

    Mars QuietPro 10-CSI-Spec Revised 4/27/2023 MARS AIR SYSTEMS, LLC Verification Samples: For each finish product specified, two samples, minimum size 6.25 inches (160 mm) square, representing actual product, color, and patterns. Manufacturer's Certificates: Certify products meet or exceed specified requirements.
  • Page 22 MARS AIR SYSTEMS, LLC PART 2 PRODUCTS MANUFACTURER Acceptable Manufacturer: Mars Air Systems, LLC; 14716 South Broadway St., Gardena, CA 90248. Tel: (310) 532-1555 or (800) 421-1266. Fax: (310) 324-3030. Email: info@marsair.com. Web: www.marsair.com. Delete one of the following two paragraphs: coordinate with requirements of Division 1 section on product options and substitutions.
  • Page 23 Mars QuietPro 10-CSI-Spec Revised 4/27/2023 MARS AIR SYSTEMS, LLC Unheated: 20 inches deep by 12 inches high (including discharge nozzle) by width of unit. Electric Heated: 20 inches deep by 12 inches high (including discharge nozzle) by width of unit.
  • Page 24 Mars QuietPro 10-CSI-Spec Revised 4/27/2023 MARS AIR SYSTEMS, LLC QP10120-3: 120 Inch (3050 mm) Wide Units: 2084 feet/min (10.6 m/s) three 1/2HP motor/fan assemblies. QP10144-3: 144 Inch (3660 mm) Wide Units: 1730 feet/min (8.8 m/s) three 1/2HP motor/fan assemblies. Air Speed at Floor: Minimum of 400 fpm (2 m/s) at 3 feet (914 mm) from the floor.
  • Page 25 Mars QuietPro 10-CSI-Spec Revised 4/27/2023 MARS AIR SYSTEMS, LLC Coils: Certified in accordance with AHRI 410. Connections: Opposite end. Connections: Same end, right hand. Connections: Same end, left hand. Casing: One-piece unpainted galvanized steel, bolted to air curtain housing. Supply and return fittings on top of casing.
  • Page 26 Mars QuietPro 10-CSI-Spec Revised 4/27/2023 MARS AIR SYSTEMS, LLC Electrical components UL/CUL listed. Optional Digital Programmable Controller: WiFi enabled controller for wireless interface with field supplied smartphone, tablet or computer No download or app required for wireless interface Wireless control range up to minimum of 50 feet from controller...
  • Page 27 Mars QuietPro 10-CSI-Spec Revised 4/27/2023 MARS AIR SYSTEMS, LLC Optional remote mounted high resolution 7” Color LCD Display with resistive touchscreen technology Fully programmable controller Connect and control via any web browser Factory built wireless router with over 50 feet range Pre-set and fully customizable programs Time delay (Passive &...
  • Page 28 Mars QuietPro 10-CSI-Spec Revised 4/27/2023 MARS AIR SYSTEMS, LLC PART 3 EXECUTION EXAMINATION Verify that required utilities are in correct location and are of correct capacities for specified products. Verify openings to receive air curtains are plumb, level, square, accurately aligned, correctly located, and in tolerance.
  • Page 29 Mars QuietPro 10-CSI-Spec Revised 4/27/2023 MARS AIR SYSTEMS, LLC Repair minor damages to finish in accordance with manufacturer's instructions and as approved by Architect. Remove and replace damaged components that cannot be successfully repaired as determined by Architect. PROTECTION Protect materials and finish from damage until substantial completion.
  • Page 30 QuietPro Series CSI spec (Word doc) NOTE: MARS AIR SYSTEMS, LLC reserves the right to change specifications and product design without notice. Such revisions do not entitle the buyer to corresponding changes, improvements, additions, or replacements for previously purchased equipment.

Table of Contents