Electrical installation
3.4

EMC advice

Note: 12 V variant only on request
The devices adhere to the EU guidelines 2004/108/EC and the technical standard EN 61800-3 provided
that the following conditions are observed:
Mounting:
The device is conductively mounted on a 500 x 500 x 5 mm bright aluminium mounting plate.
The mounting plate must be connected to earth using a 10 mm² wire.
The motor housing must be connected to earth using a 10 mm² wire.
The device ground X-AGND must be connected to the mounting plate using a 1.5 mm² wire.
Device PE screw X3:6 connected to the mounting plate using a 4 mm² wire.
Connection of the control conductors:
All control conductors must be shielded. Analogue signal lines must be twisted and shielded. The shield
must have surface-to-surface contact with the mounting plate (earth).
Battery connection:
12..360
V dc voltage
Edition: 2020 / V4