Basic informationen
Ambient conditions
Protection rating
Standards
Over-voltage
Operating temperature range
Storage and transport
Installation altitude
Cooling
Mounting position
Contamination
Vibration
Shock
Environmental conditions
Humidity
Edition: 2020 / V4
IP 65
EN60204, ISO 16750 , EN61800, IEC60146
400 V and 700 V DC +10 %
-30 to +85 °C
-30 °C to +80 °C EN60721
≤ 1000m above sea level 100 %,
>1000m performance reduced by 2 %/100 m
Liquid cooling unit max. 65°C, 12 l/min,
pressure max. 6 bar
> 65°C performance reduced by 2 %/°C
independent
Contamination degree 2 acc. to EN 61800-5-1
10 Hz to 58 Hz ampl. 0.075 mm
according IEC 60068-2-3
58..200 Hz 1 g
15 g for 11 ms
Not permissible:
condensation (dew), ice formation, oil mist, salt spray, water
class F, humidity < 85 %
condensation not allowed!