Brinkmann Immersions pumps of the series TH/STH11 ... TH/STH17 Contents 9 Trouble shooter’s guide ........12 Indication to the manual ........2 Description of product ........2-6 10 Spare part ..........13-15 Safety instructions ..........9 11 Repair ............. 15 Transport and storage ........
Page 3
Technical data 50 Hz Max. del. Max. del. Height Depth of Weight Power Noise pressure volume immersion level bar / Type spec. weight 1 l/min H mm h mm (S)TH1102A180 (S)TH1103A180 (S)TH1104A280 (S)TH1105A280 (S)TH1106A280 (S)TH1107A310 (S)TH1108A380 (S)TH1109A380 10.7 (S)TH1110A470 11.9 (S)TH1111A470 13.0 (S)TH1112A470...
Page 4
50 Hz Max. del. Max. del. Height Depth of Weight Power Noise pressure volume immersion level bar / Type spec. weight 1 l/min H mm h mm (S)TH1402A180 (S)TH1403A280 (S)TH1404A280 (S)TH1405A380 (S)TH1406A380 (S)TH1407A470 10.0 (S)TH1408A470 11.8 (S)TH1409A570 12.1 (S)TH1410A570 14.3 (S)TH1411A660 16.0 S)TH1412A660...
Page 5
50 Hz Max. del. Max. del. Height Depth of Weight Power Noise pressure volume immersion level bar / Type spec. weight 1 l/min H mm h mm (S)TH1702A180 (S)TH1703A280 (S)TH1704A280 (S)TH1705A380 (S)TH1706A380 (S)TH1707A470 10.4 (S)TH1708A470 12.0 (S)TH1709A570 13.7 11.0 (S)TH1710A570 15.0 (S)TH1711A660 16.4...
Page 6
60 Hz Max. del. Max. del. Height Depth of Weight Power Noise pressure volume immersion level bar / Type spec. weight 1 l/min H mm h mm (S)TH1102B180 1.49 (S)TH1103B180 2.18 (S)TH1104B280 2.94 (S)TH1105B280 (S)TH1106B280 10.1 4.55 (S)TH1107B310 11.9 5.75 (S)TH1108B380 13.8 (S)TH1109B380...
Page 7
60 Hz Max. del. Max. del. Height Depth of Weight Power Noise pressure volume immersion level bar / Type spec. weight 1 l/min H mm h mm (S)TH1402B180 2.94 (S)TH1403B280 4.55 (S)TH1404B280 (S)TH1405B380 10.2 (S)TH1406B380 12.2 (S)TH1407B470 14.4 10.3 (S)TH1408B470 16.4 12.6 (S)TH1409B570...
Page 8
60 Hz Max. del. Max. del. Height Depth of Weight Power Noise pressure volume immersion level bar / Type spec. weight 1 l/min H mm h mm (S)TH1702B180 (S)TH1703B280 5.75 (S)TH1704B280 (S)TH1705B380 10.8 10.3 (S)TH1706B380 13.1 12.6 (S)TH1707B470 15.2 15.0 (S)TH1708B470 17.4 (S)TH1709B570...
3 Safety instructions Safety instructions relevant for operation When operating the pump, the safety instructions • If hot or cold machine components involve haz- contained in this manual, the relevant national ards. they must be guarded against accidental accident prevention regulations and any other ser- contact.
5 Installation and Connection Electric wiring Mechanical installation During any assembly or disassembly process the pumps must be secured against tipping trough ropes for example at all times. Pumps must be mounted securely. Piping, tank and All service work must be carried out by qualified pumps must be mounted without any tension.
6 Start up / Shut down Start up ATTENTION Attention! Potential Risk of Burning! Switch off at the mains. Surface temperatures above 50°C do occur After connection the electrical wires, close the during regular operation, i.e. on the surfaces of terminal box.
9 Trouble shooter’s guide Fault Cause Remedy Motor does not start, no motor At least two of the power supply Check fuses, terminals and supply noise leads have failed leads. Overload has tripped Inspect overload Motor does not start, humming One of the supply leads has failed See above noise...
10 Spare part 10.1 Spare part list for the immersion pumps of the series TH/STH11 TH/STH1702A180...TH/STH1710A570 TH/STH1402A180...TH/STH1413A760 TH/STH1702B180...TH/STH1706B380 TH/STH1402B180...TH/STH1408B470 Item Description Stator with terminal board Motor flange End shield Motor shaft with rotor Terminal box up to 5.5 kW Terminal box frame from 7.5 kW and over Terminal box cover from 7.5 kW and over Fan cover 10 Gasket...
Page 14
10.2 Spare part list for the immersion pumps of the series TH/STH1711A660...TH/STH1717A900 TH/STH1414A760...TH/STH1417A900 TH/STH1707B470...TH/STH1711B660 TH/STH1409B570...TH/STH1412B660 Item Description Motor Bearing housing Bearing shaft Woodruff key DIN 6888 Ball bearing DIN 628 Distance plate Ball bearing DIN 628 Coupling Socket head cap screw DIN 912 10 Threaded pin DIN 705...
10.3 Indications to the spare part order 9) Lubricate the O-ring seal (72) of the pump body (50), screw and put on the stud bolt (71), the Spare parts are available from the supplier. Standard commercially available parts are to be hexagon cap nuts (81) and the pump casing (67).
Brinkmann Pumpen, K. H. Brinkmann GmbH & Co. KG Friedrichstraße 2 D-58791 Werdohl Germany This declaration of conformity is issued under the sole responsibility of Brinkmann Pumps and belongs to the following product. Product name Immersion pumps TH/STH11 … 17...
Page 17
13.2 EC declaration of conformity DEUTSCH / ENGLISH /FRANÇAIS / ESPAÑOL EG-Konformitätserklärung EC declaration of conformity / Déclaration de conformité CE / Declaración de conformidad CE Hersteller / Manufacturer / Constructeur / Fabricante Brinkmann Pumpen, K. H. Brinkmann GmbH & Co. KG Friedrichstraße 2, D-58791 Werdohl Produktbezeichnung / Product name / Désignation du produit / Designación del producto Tauchpumpen / Immersion pumps / Pompes plongeantes / Bombas de inmersión...
Need help?
Do you have a question about the STH17 Series and is the answer not in the manual?