Brinkmann Immersions pumps of the series STA/SAL1602…2003, SGL1402…1702 Contents 9 Trouble shooter’s guide ........7 Indication to the manual ........2 Description of product ........2-3 10 Spare part ............8-9 Safety instructions ..........4 11 Repair ............... 9 Transport and storage ........4 12 Disposal ............
Page 3
Technical data Max. del. Max. del. Height Depth of Weight Power Noise pressure volume immersion 50 / 60 Hz level 1, 2) bar / spec. Type Type weight 1 l/min H mm h mm g kg dBA /50 Hz STA1602 / 410 SAL1602 / 420 2150 18.5 / 21.3...
Safety instructions relevant for operation 3 Safety instructions • If hot or cold machine components involve When operating the pump, the safety instructions contained in this manual, the relevant national hazards, they must be guarded against acci- accident prevention regulations and any other dental contact.
5 Installation and Connection Electric wiring Mechanical installation During any assembly or disassembly process the pumps must be secured against tipping trough ropes for example at all times. Pumps must be mounted securely. Piping, tank and All service work must be carried out by quali- pumps must be mounted without any tension.
6 Start up / Shut down Start up ATTENTION If the pump should lock up and cease, shut Switch off at the mains. pump down (see 6.2) and disconnect from After connection the electrical wires, close the power supply. Pump must be uninstalled and terminal box.
9 Trouble shooter’s guide Fault Cause Remedy Motor does not start, no motor At least two of the power supply Check fuses, terminals and supply noise leads have failed leads . Overload has tripped Inspect overload Motor does not start, humming noise One of the supply leads has failed See above Impeller faulty...
10 Spare part 10.1 Spare part list for the immersion pumps of the series STA/SAL1602…2003, SGL1402…1702 Item Description Motor Bearing housing Woodruff key DIN 6888 Bearing shaft Ball bearing DIN 628 Ball bearing DIN 628 Socket head cap screw DIN 912 Bearing cover Coupling 10 Nilos-ring...
10.2 Indications to the spare part order 11.2 Assembling the insert shaft and motor shaft Spare parts are available from the supplier. Standard commercially available parts are to be ATTENTION purchased in accordance with the model type. The ordering of spare parts should contain the Clean the contact surfaces of the insert shaft (2) following details: (inside) and the motor shaft (3).
Manufacturer Brinkmann Pumpen, K. H. Brinkmann GmbH & Co. KG Friedrichstraße 2 D-58791 Werdohl Germany This declaration of conformity is issued under the sole responsibility of Brinkmann Pumps and belongs to the following product. Product name Immersion pumps STA/SAL1602…2003, SGL1402…1702...
Page 11
13.2 EC declaration of conformity DEUTSCH / ENGLISH /FRANÇAIS / ESPAÑOL EG-Konformitätserklärung EC declaration of conformity / Déclaration de conformité CE / Declaración de conformidad CE Hersteller / Manufacturer / Constructeur / Fabricante Brinkmann Pumpen, K. H. Brinkmann GmbH & Co. KG Friedrichstraße 2, D-58791 Werdohl Produktbezeichnung / Product name / Désignation du produit / Designación del producto Tauchpumpen / Immersion pumps / Pompes plongeantes / Bombas de inmersión...
Need help?
Do you have a question about the STA1602/410 and is the answer not in the manual?
Questions and answers