It is always to be kept available at Limit of Application (Table 1) the installation site. Type STE141...146 STL141...146 Identification of safety instructions in the operating manual Mediums Cooling emulsions, cooling- and...
Page 3
1, 2) bar / spec. Type Type weight 1 l/min H mm h mm g kg dBA / 50 Hz STE141 / 120 STL141 / 150 19.0 22.5 0.63 / / 200 / 230 20.0 23.0 0.725 / 270 / 300 21.0 24.0...
Safety instructions relevant for operation 3 Safety instructions • If hot or cold machine components involve When operating the pump, the safety instructions contained in this manual, the relevant national hazards, they must be guarded against acci- accident prevention regulations and any other dental contact.
Electric wiring 5 Installation and Connection Mechanical installation During any assembly or disassembly process the pumps must be secured against tipping trough ropes for example at all times. All service work must be carried out by quali- Pumps must be mounted securely. Piping, tank and fied service personnel.
Wiring diagram e.g. Star connection 3 x 400 V, 50 Hz resp. 380-415 V, 50 Hz Delta connection 3 x 230 V, 50 Hz resp. 220-240 V, 50 Hz There may be no foreign objects such as dirt, particles or humidity inside the terminal board. Mount terminal board cover to motor tight against dust and humidity and close up all unused wiring ports.
9 Trouble shooter’s guide Fault Cause Remedy Motor does not start, no motor At least two of the power supply Check fuses, terminals and supply noise leads have failed leads . Overload has tripped Inspect overload Motor does not start, humming noise One of the supply leads has failed See above Impeller faulty...
10 Spare part 10.1 Spare part list for the immersion pumps of the series STE/STL141 ... 146 Item Description Stator with terminal board Motor flange End shield Terminal box Fan cover Ball bearing up to 1.1 kW DIN 625 Ball bearing up 1.7 kW DIN 628 10 Ball bearing DIN 625...
Manufacturer Brinkmann Pumpen, K. H. Brinkmann GmbH & Co. KG Friedrichstraße 2 D-58791 Werdohl Germany This declaration of conformity is issued under the sole responsibility of Brinkmann Pumps and belongs to the following product. Product name Immersion pumps STE/STL141…146 Type The named product described above complies with the following statutory requirements of United Kingdom: UK SI 2008 No.
Page 11
13.2 EC declaration of conformity DEUTSCH / ENGLISH /FRANÇAIS / ESPAÑOL …………. EG-Konformitätserklärung EC declaration of conformity / Déclaration de conformité CE / Declaración de conformidad CE Hersteller / Manufacturer / Constructeur / Fabricante Brinkmann Pumpen, K. H. Brinkmann GmbH & Co. KG Friedrichstraße 2, D-58791 Werdohl Produktbezeichnung / Product name / Désignation du produit / Designación del producto Tauchpumpen / Immersion pumps / Pompes plongeantes / Bombas de inmersión...