Accessing the Analyzer Probe Port

4.2.3
Benchmark units contain a 1/4" NPT port on the side of the exhaust manifold, as shown in
Figure 4-2. Prepare the port for the combustion analyzer probe as follows:
Analyzer Probe Port Access Instructions
1. Refer to Figure 4-2 and remove the 1/4" NPT plug from the exhaust manifold.
2. If necessary, adjust the stop on the combustion analyzer probe so it will extend mid-way into the flue
gas flow. DO NOT install the probe at this time.
EXHAUST MANIFOLD
ANALYZER PROBE
Figure 4-2: Analyzer Probe Port Location – BMK750 & 1000 Shown