► Install the transmitter and the receiver using the supplied mounting accessories
so that they are exactly opposite each other.
► Align the transmitter and the receiver so that they are in parallel at the same
height and the plugs face the same direction.
If vibrations are to be expected in your applications, it is recommended to
use vibration dampers (available as accessory).
Adjustable brackets can be used to ensure easy optical alignment (available
as accessories).

6.5.1 Optical alignment

T
T = transmitter; R = receiver
The indication LEDs of the receiver help to correctly align the photoelectric safety
sensors.
► Align the transmitter so that the green LED of the receiver lights.
► Fix the transmitter and the receiver.
R T
R
T
R
T