6.4 Horizontal installation of the safety light curtains

These versions are suitable for primary guarding for bodies or parts of
bodies.
With horizontal installation it has to be noted that the distance between the outer
border of the hazardous area (A) and the outer light beam of the safety light
curtain is greater than or equal to the minimum safety distance (S). It is calculated
as follows:
S = 1600 (t
with H being the height of the protected area of the
reference level (G) of the machine;
In this example the following applies: H < 1 m (to ISO
13855).
A = hazardous area
H = height

6.5 Fixing and optical alignment

Correct alignment of the transmitter and the receiver is decisive for the
proper function of the photoelectric safety sensors.
14
+ t
) + 1200 – 0.4 H
1
2
H = 15 (d - 50)
G
S = min. safety distance
G = reference level
S
A
H