F1145-15
Rated voltage
Starting current
Max operating current including 0 kW immersion heater (Recommended fuse rating).
Max operating current including 1 – 2 kW immersion heater (Recommended fuse rating).
Max operating current including 3 – 4 kW immersion heater (Recommended fuse rating).
Max operating current including 5 – 6 kW immersion heater (Recommended fuse rating).
Max operating current including 7 kW immersion heater, connected on delivery (Recommended fuse rating).
Max operating current including 9 kW immersion heater, requires reconnection (Recommended fuse rating).
Additional power
Output, Brine pump
Output, Heating medium pump
Enclosure class
Equipment Compliant with IEC 61000-3-12
For Connection Design Purposes, Compliant with IEC 61000-3-3 technical requirements
F1145-17
Rated voltage
Starting current
Max operating current including 0 kW immersion heater (Recommended fuse rating).
Max operating current including 1 – 2 kW immersion heater (Recommended fuse rating).
Max operating current including 3 – 4 kW immersion heater (Recommended fuse rating).
Max operating current including 5 – 6 kW immersion heater (Recommended fuse rating).
Max operating current including 7 kW immersion heater, connected on delivery (Recommended fuse rating).
Max operating current including 9 kW immersion heater, requires reconnection (Recommended fuse rating).
Additional power
Output, Brine pump
Output, Heating medium pump
Enclosure class
Equipment Compliant with IEC 61000-3-12
For Connection Design Purposes, Compliant with IEC 61000-3-3 technical requirements
74
Chapter 12 | Technical data
400V 3N ~ 50Hz
A
43
rms
A
11(16)
rms
A
20(20)
rms
A
20(20)
rms
A
20(20)
rms
A
24(25)
rms
A
26(30)
rms
kW
1/2/3/4/5/6/7 (switchable to 2/4/6/9)
W
35 – 185
W
10 – 87
IPX1B
400V 3N ~ 50Hz
A
52
rms
A
13(16)
rms
A
22(25)
rms
A
22(25)
rms
A
22(25)
rms
A
26(30)
rms
A
28(30)
rms
kW
1/2/3/4/5/6/7 (switchable to 2/4/6/9)
W
35 – 185
W
10 – 87
IPX1B
NIBE F1145

Advertisement

Table of Contents
loading

This manual is also suitable for:

F1145-15F1145-17F1145-6F1145-8F1145-10F1145-12 ... Show all