Nibe F1145 Series Installation Manual page 56

Ground source heat pump
Hide thumbs Also See for F1145 Series:
Table of Contents

Advertisement

max. fan speed: Here, you set the highest permitted
fan speed during demand-controlled ventilation.
min. fan speed: Here, you set the lowest permitted fan
speed during demand-controlled ventilation.
contr. sensor 1 – 4: Here, you select which exhaust air
module(s) will be affected by which HTS unit(s). If two
or more HTS units control an exhaust air module, the
ventilation is adjusted base on the units' average value.
time between speed changes: Here, you set the time
it takes for the exhaust air module to increase/decrease
the fan speed step-by-step until the desired relative hu-
midity is obtained. At the factory setting, the fan speed
is adjusted by one percentage point every ten minutes.
TIP
See the installation instructions for ERS and
HTS for a function description.
MENU 5.3.15 - GBM COMMUNICATION
MODULE
start diff additional heat
Setting range: 10 – 2,000 DM
Factory setting: 400 DM
hysteresis
Setting range: 10 – 2,000 DM
Factory setting: 100 DM
Make settings for the gas boiler GBM 10-15 here. For
example . you can select when the gas boiler is to start.
See the accessory installation instructions for a descrip-
tion of function.
MENU 5.3.16 - HUMIDITY SENSOR
climate system 1 HTS
Setting range: 1–4
Default value: 1
limit RH in the room, syst.
Setting range: on/off
Factory setting: off
prevent condensation, syst.
Setting range: on/off
Factory setting: off
limit RH in the room, syst.
Setting range: on/off
Factory setting: off
Up to four humidity sensors (HTS 40) can be installed.
56
Chapter 8 | Control - Menus
Here you select whether your system(s) is/are to limit
the relative humidity level (RH) during heating or cooling
operation.
You can also choose to limit min. cooling supply and
calculated cooling supply to prevent condensation on
pipes and components in the cooling system.
See the Installer Manual for HTS 40 for function descrip-
tion.
MENU 5.3.22 - PHOTOVOL CONTROL
affect room temperature
Setting range: on/off
Factory setting: off
affect hot water
Setting range: on/off
Factory setting: off
Here you set whether you want EME 10 to affect the
room temperature and / or the hot water.
See the accessory installation instructions for function
description.
MENU 5.4 - SOFT IN/OUTPUTS
Here, you state where the external switch function has
been connected to the terminal block, either to one of
5 AUX inputs or to output AA3-X7.
MENU 5.5 - FACTORY SETTING SERVICE
All settings can be reset (including settings available to
the user) to default values here.
Caution
When resetting, the start guide is displayed
the next time the heat pump is restarted.
MENU 5.6 - FORCED CONTROL
You can force control the different components in the
heat pump and any connected accessories here.
NOTE
Forced control is only intended to be used for
troubleshooting purposes. Using the function
in any other way may cause damage to the
components in your climate system.
MENU 5.7 - START GUIDE
When the heat pump is started for the first time the
start guide starts automatically. Start it manually here.
See
page 32
for more information about the start guide.
MENU 5.8 - QUICK START
It is possible to start the compressor from here.
NIBE F1145