MOTOR PROTECTION BREAKER /MINIATURE
CIRCUIT BREAKER
Motor protection breaker (AA11-FC10) / miniature circuit
breaker (AA11-FC1) cuts the power to the compressor
if the current is too high. It is located behind the front
cover and is reset manually.
Caution
Check the miniature circuit-breaker, temperat-
ure limiter and motor protection breaker. They
may have tripped during transportation.
ACCESSIBILITY, ELECTRICAL CONNECTION
The plastic cap of the electrical boxes is opened using
a screwdriver.
NOTE
The door to the input card circuit board is
opened using a Torx 20 screwdriver.
Removing the cover, input circuit board
1.
Unscrew the screws and angle out the cover.
NIBE F1145
2.
Pull off the cover.
Removing the hatch, electrical cabinet
1.
Disconnect the contacts.
Unscrew the screws and angle out the cover.
2.
Chapter 5 | Electrical connections