Nibe F1145 Series Installation Manual page 34

Ground source heat pump
Hide thumbs Also See for F1145 Series:
Table of Contents

Advertisement

F1145 15 and 17 kW
Pumpkapacitet, köldbärarsida för F1145/F1245 15-17kW.
Available pressure, kPa
Tillgängligt tryck, kPa
Electrical output, W
Eleffekt, W
200
180
160
140
120
100
80
60
40
P40%
20
40%
0
0,0
0,10 0,20 0,30 0,40 0,50 0,60 0,70 0,80 0,90
Heating medium side
F1145 has a heating medium pump that can be automat-
ically controlled. For manual operation: deactivate "auto"
Tillgängligt tryck, kPa
in menu 5.1.11 and then set the speed according to the
Eleffekt, W
diagrams below.
80
The flow must have a suitable temperature difference
for the operating case (heating operation: 5 - 10 °C, hot
70
water generation: 5 - 10 °C, pool heating: approx. 15 °C)
60
between controlling supply temperature sensor and re-
50
turn line sensor. Check these temperatures in menu 3.1
"service info" and adjust the heating medium pump
40
(GP1) speed until the temperature difference is attained.
30
A high difference indicates a low heating medium supply
and a low difference indicates a high heating medium
20
supply.
10
Read off what speed the heating medium pump should
0
have during manual operation from the diagrams below.
0,0
0,05
0,10
0,15
Tillgängligt tryck, kPa
Available pressure, kPa
Electrical output, W
p
Eleffekt, W
F1145 6 kW
Pumpkapacitet, värmebärarsida för F1145/F1245 6kW.
Available pressure, kPa
Tillgängligt tryck, kPa
Electrical output, W
Eleffekt, W
80
70
60
50
40
30
20
10
0
0,0
0,05
0,10
0,15
34
Chapter 6 | Commissioning and adjusting
P100%
P80%
P60%
100%
60%
80%
Flöde l/s
Flow l/s
P60%
2
P40%
1
0,20
0,25
0,30
0,35
P100%
P80%
100%
P60%
80%
P40%
60%
40%
0,20
0,25
0,30
0,35
0,40
Flöde l/s
Flow l/s
F1145 8 and 12 kW
Pumpkapacitet, värmebärarsida för F1145/F1245 8 och 12kW.
Available pressure, kPa
Tillgängligt tryck, kPa
Electrical output, W
Eleffekt, W
80
70
60
50
40
30
20
10
0
1,0
0,0
0,05
0,10
F1145 10 kW
Pumpkapacitet, värmebärarsida för F1145/F1245 10kW.
Available pressure, kPa
Tillgängligt tryck, kPa
Electrical output, W
Eleffekt, W
80
70
60
50
P100%
40
30
P80%
20
10
4
0
3
0,0
0,05
0,10
F1145 15 and 17 kW
Pumpkapacitet, värmebärarsida för F1145/F1245 15-17kW.
0,40
0,45
Available pressure, kPa
Tillgängligt tryck, kPa
Electrical output, W
Flöde l/s
Eleffekt, W
90
80
70
60
50
40
30
20
10
0
0,0
0,05 0,10 0,15 0,20 0,25 0,30 0,35 0,40 0,45 0,50
Readjusting, venting, heat medium side
Air is initially released from the hot water and venting
0,45
may be necessary. If gurgling sounds can be heard from
the heat pump or climate system, the entire system
requires additional venting. Check the pressure in the
pressure expansion vessel (CM1) with the pressure
gauge (BP5). If the pressure drops, the system should
be replenished.
P80%
80%
P60%
60%
P40%
40%
0,15
0,20
0,25
0,30
0,35
P60%
60%
P40%
40%
0,15
0,20
0,25
0,30
P80%
80%
P60%
60%
40%
P40%
NIBE F1145
P100%
100%
0,40
0,45
Flöde l/s
Flow l/s
P100%
100%
P80%
80%
0,35
0,40
Flöde l/s
Flow l/s
P100%
100%
Flöde l/s
Flow l/s

Advertisement

Table of Contents
loading

This manual is also suitable for:

F1145-15F1145-17F1145-6F1145-8F1145-10F1145-12 ... Show all