Norac UC4.5 EVRARD Installation Manual

Norac UC4.5 EVRARD Installation Manual

Spray height control system
Hide thumbs Also See for UC4.5 EVRARD:

Advertisement

EVRARD – Auto Slant
End User Installation Manual
EV5-E

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the UC4.5 EVRARD and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Norac UC4.5 EVRARD

  • Page 1 EVRARD – Auto Slant End User Installation Manual EV5-E...
  • Page 2 Reorder P/N: UC4.5-BC-EV5-INSTE Rev A (EVRARD - Auto Slant – End User) NOTICE: NORAC Systems International Inc. reserves the right to improve products and their specifications without notice and without the requirement to update products sold previously. Every effort has been made to ensure the accuracy of the information...
  • Page 3: Table Of Contents

    Contents Introduction ........................ 1     List of Parts ......................... 1     Control Panel Installation ..................2     Cable Installation ....................... 2     Calibration ........................3     UC4.5 Menu Structure ....................6    ...
  • Page 4: Introduction

    1 Introduction Congratulations on your purchase of the NORAC UC4.5 Spray Height Control System. This system is manufactured with top quality components and is engineered using the latest technology to provide operating reliability unmatched for years to come. When properly used the system can provide protection from sprayer boom damage, improve sprayer efficiency, and ensure chemicals are applied correctly.
  • Page 5: Control Panel Installation

    3 Control Panel Installation Install the UC4.5 Control Panel (E01) in the cab of the sprayer with the supplied mounting bracket. The location must facilitate connecting the power cable (C10) to the back of the UC4.5 Control Panel. 4 Cable Installation Figure 1: Cable Connections 1.
  • Page 6: Calibration

    Calibration Initial Power Up 1. Turn on the power for the UC4.5 Control Panel using the switch on the side of its chassis. Ensure that the UC4.5 display lights up to confirm that the panel has +12 volt power. 2. After a moment the panel will display the Main Run Screen: M 90 M ReTune 1.
  • Page 7 Calibrating the Slant Valve The roll (slant) valve can only be calibrated manually as described below. When calibrating the roll valve, calibrate the deadzone clockwise and counter clockwise settings first and then the gain clockwise and counter clockwise settings. Navigating to the Slant Valve Settings: 1.
  • Page 8 5. The change in height reading is live as long as the button is held. Wait until the height reading has settled to a stable value and record this reading. 6. Average three readings. The acceptable average change in height should be from 20 to 50 7.
  • Page 9: Uc4.5 Menu Structure

    UC4.5 Menu Structure...
  • Page 10 Canada NORAC Systems International Inc. Phone: (+1) 306 664 6711 Toll Free: 1 800 667 3921 Shipping Address: 3702 Kinnear Place Saskatoon, SK S7P 0A6 United States NORAC, Inc. Phone: (+1) 952 224 4142 Toll Free: 1 866 306 6722...

Table of Contents