Advertisement

Quick Links

Selador CE Series by ETC
Lustr – Paletta – Vivid – Vivid-R –
Vivid Fire – Vivid Ice– Pearl
User Manual
2010-09
The Selador series of fixtures are intended for professional use only.
Read entire User Manual before using equipment.
C o p y r i g h t © 2 0 1 0 . E le c tr o n i c T h e a t r e C o n t r o l s , I n c .
A l l r i g h t s r e s e r v e d .
P r o d u c t in f o r m a t i on a n d s p e c i f i c a t i o n s s u bj e c t t o c h a n g e .
P a r t N u m b e r : 7 4 0 1 M 1 2 1 0 R e v C
R e le a s ed : 2 0 1 0 - 0 9

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Selador CE Series and is the answer not in the manual?

Questions and answers

Summary of Contents for ETC Selador CE Series

  • Page 1 Selador CE Series by ETC Lustr – Paletta – Vivid – Vivid-R – Vivid Fire – Vivid Ice– Pearl User Manual 2010-09 The Selador series of fixtures are intended for professional use only. Read entire User Manual before using equipment.
  • Page 2 E T C a n d S e l a d o r a r e r e g i s t e r e d t r a d e m a r k s o f E l e c t r o n i c T h e a tr e C o n t r o l s , I n c . i n t h e U n it e d S t a t e s a n d o t h e r c o u n tr i e s .
  • Page 3 DECLARATION OF CONFORMITY We, Electronic Theatre Controls Limited declare under sole responsibility that the product: Product name: Selador LED luminaire Product type/model: Vivid, Vivid-R, Lustr, Pearl, Paletta, Vivid Fire & Vivid Item numbers: All sizes to which this declaration relates is in conformity with the following Standards: EN 60598-1:2004 Luminaires.
  • Page 5: Table Of Contents

    T a b l e o f C o n t e n t s Specifications ....1 Maximum Power Consumption at Full Intensity ..2 Dimensions and LEDs .
  • Page 6: Specifications

    Specifications N o t e : Vivid-R replaces the original Vivid fixture as of February 2010. The manufacturer of the K2 LED emitter is phasing out these emitters over the next year. Vivid-R maintains photometrics equivalent to the original Vivid with higher intensity and uses less power. Physical •...
  • Page 7: Maximum Power Consumption At Full Intensity

    Control • DMX512-A compliant • Internal control electronics for smooth low-end dimming at 15-bit resolution • DMX in and thru via 5-pin XLR connectors • 21 fixture provides 2 independently controllable cells • 8-channel (7 colour plus intensity) • 42 fixture provides 4 independently controllable cells •...
  • Page 8: Dimensions And Leds

    Dimensions and LEDs L u s tr , V i v i d , V i v i d - R , V i v i d F i r e, V i v i d I c e , a n d P e a r l Size in millimeters Number of LEDs Model...
  • Page 9: Overview

    • Specialized LED array • High output warm and cool white LEDs for variable colour temperature white (only) light output from 3200 to 5700K. Information in this manual is applicable to all Selador Series by ETC products unless stated otherwise.
  • Page 10: Applications

    Cyc light If you have questions about your Selador series fixture that are not answered in this manual, please contact the supplier of your ETC equipment or ETC Technical Services. A m e r i c a s U n i t e d K i n g d o m Electronic Theatre Controls Inc.
  • Page 11: Document Conventions

    Document Conventions Throughout this manual, the following are used to alert you to notes and safety notices. N o t e : Notes are helpful hints and information that is supplemental to the main text. C A U T I O N : A Caution statement indicates situations where there may be undefined or unwanted consequences of an action, potential for data loss or an equipment problem.
  • Page 12: Installation

    Installation Power and Data Cabling Requi rements P o w e r The Selador series fixture operates on AC power, 100 to 240VAC/50-60Hz. You may use a circuit powered through an SCR dimmer, as long as the dimmer is set to unregulated non-dim (switched) operation.
  • Page 13: Installation Procedures

    Installation Procedures I n s t a l l i n g M o u n t i n g H a r d w a r e Four different options are provided for mounting Selador fixtures. • Yoke for 11 and 21 fixtures •...
  • Page 14 180mm 180mm 235mm 180mm 180mm 290mm 265mm 255mm Floor trunnion dimensions 290mm 315mm 180mm 345mm 235mm 180mm (225mm Paletta) (160mm Paletta) Hanging dimensions 235mm (225mm Paletta) Hanging bracket Front view dimensions 27.9cm 54.6cm 108cm 161.3cm Rear view to show power, data connections, and repeating addressing and fan locations Selador Series User Manual...
  • Page 15: Safety Cable

    S a f e t y C a b l e The safety cable (or other approved safety device) should be attached to the fixture housing and wrapped around the hanging structure (pipe). Appropriate attachment points (holes) are provided in the protruding tabs on either end of the fixture housing. Take care to leave as little slack as possible in the safety cable to avoid the cable catching the yoke of the fixture.
  • Page 16: Installing Secondary Lenses

    I n s t a l l i n g S e c o n d a r y L e n s e s Up to two secondary lenses can be installed in the slots towards the front of the fixture. The stacking order and distance from the LED array are not important to the function of the lenses.
  • Page 17: Connections And Addressing

    C o n n e c t i o n s a n d A d d r e s s i n g Connect AC input power and DMX data cables to the appropriate ports as shown below. DMX Thru DMX Input Power Fuse...
  • Page 18: Control

    C o n t r o l Use the two push buttons on the bottom of the fixture to set the starting address for the fixture. View the LED display with the push buttons on the left. The top push button increases the number and the bottom push button decreases the number.
  • Page 19 Each cell of a Selador Series fixture occupies eight DMX channels. Seven are individual colours and the eighth is the master intensity. The table below describes the order and function of each address. L u s tr , P a l e t t a , a n d V i v i d - R Data Channel Colour Value...
  • Page 20 C o l o u r M a t c h i n g This information will be provided in a future release of this manual. Selador Series User Manual...
  • Page 21: Routine Maintenance

    Routine Maintenance General Fixture Cleaning To ensure optimum performance of your Selador series fixture, you should perform the following inspections and cleanings at least once a year. You may need to inspect or clean the fixture more often, depending on the type and amount of use your fixture experiences during the year.
  • Page 22: Cooling Fan Filter Cleaning

    Cooling Fan Fi lter Cleaning  Cooling fan filters should be inspected at a minimum every six months; more frequently if fixtures are powered on for more than four hours per day  Use a vacuum cleaner to remove dust from each fan filter ...
  • Page 24    Service: (Americas) service@etcconnect.com (UK) service@etceurope.com (DE) techserv-hoki@etcconnect.com (Asia) service@etcasia.com    Web: www.etcconnect.com Copyright © 2010 ETC. All Rights Reserved. Product information and specifications subject to change.   7401M1210 Rev C Released 2010-09  ...