• If you do not want to change the phone number, leave this setting at NO. Press SCROLL to advance
to the next setting.
• To change the number, select YES; Press the UP or DOWN ARROW and then enter the service phone
number. Press SCROLL to advance through the digits. After setting the number, press SCROLL to
advance to the next settings.
3. TIME OF DAY
The control will display:
Set
Time of Day
• Press the UP or DOWN ARROW to program the time of day.
Press the SCROLL BUTTON to advance to the next setting.
The control will display:
Go to ADVANCED menu ?
If you want to go to advanced setting, press the UP or DOWN ARROW, change to YES and press the
SCROLL BUTTON. (see ADVANCED MENU below)
If you do not want to access advance setting, leave this at NO. Press Scroll to advance to Exit screen.
To Exit Press Down Arrow
Press the DOWN ARROW to exit the Installer's Level.
Note: If you need to recheck settings or make a change, pressing SCROLL when "EXIT" is
displayed will take you back to the start of Installer Settings.
IMPORTANT NOTE: TO ACTIVATE THE NEW SETTINGS, YOU MUST EXECUTE A COMPLETE
REGENERATION. IF YOU DO NOT MANUALLY REGENERATE THE SYSTEM, THE SETTINGS WILL
NOT BECOME ACTIVE UNTIL THE UNIT HAS COMPLETED THE NEXT SCHEDULED REGENERA-
TION.
ADVANCED MENU
1. RESET AVERAGE
The control will display:
Reset Average No
• If you want to reset the average daily volume, press the UP or DOWN ARROW to select YES.
• If YES is selected, the control will reset the average volume per day to 25% of the capacity.
Press the SCROLL BUTTON to advance to the next setting.
2. RESERVE CAPACITY
The control will display:
Rsrv: Variable
• The reserve capacity will be calculated automatically, based on the daily water consumption. The
initial setting is 25% of the capacity, which will adjust over time to accurately reflect daily water use.
•If you prefer, you can select a Fixed Reserve. While at the Reserve screen when "Variable" is
flashing, press the UP or DOWN ARROW. The control will display:
Rsrv: 200 GL FXd
No