Pentair CARBON FILTRATION SYSTEM 1.0 Service Manual page 11

Whole house
Hide thumbs Also See for CARBON FILTRATION SYSTEM 1.0:
Table of Contents

Advertisement

• To adjust the resreve, press the SCROLL BUTTON. Use the UP OR DOWN ARROW to set the reserve
capacity in increments to 10 gallons, upto 70% capacity of the bed.
• To calculate the reserve capacity, take the number of people in the home and multiply it by 70 gallons
per day. The reserve capacity will equal one day of water use.
Example: 3 people X 70 gallons per day = 210 gallons (suggested reserve capacity)
Press the SCROLL BUTTON to advance to the next setting.
3. TIME OF REGENERATION
The control will display:
Regen @ 1:00 am
• Press the UP or DOWN ARROW to adjust the time of regeneration.
Regeneration should be set for a time when water use is minimal.1:00 AM is good for most households.
Note: The system diverts untreated water to the home during regeneration. If any water is drawn
during regeneration, some untreated water will enter the plumbing system and possibly the hot
water tank.
Press the SCROLL BUTTON to advance to the next setting.
4. DAYS OVERRIDE
The control will display:
Override: OFF
• Press the UP or DOWN ARROW to set the number of days between regenerations. The setting range
is OFF to 30 days.
Note: In most situations with carbon filter, override can remain "OFF". Set a number of days if you
wish to have the filter be refreshed periodially regardless of water use.
Press the SCROLL BUTTON to advance to the next setting.
5. CYCLE 1 - BACKWASH
The control will display:
Backwash: 10 min
• Press the UP or DOWN ARROW to change the length of the backwash cycle. The setting range is 0
to 99 minutes.
Press the SCROLL BUTTON to advance to the next setting.
6. CYCLE 2 - BRINE/SLOW RINSE
The control will display:
BRN/RNS: 0 min
• Press the UP or DOWN ARROW to change the length of the brine/slow rinse cycle. The setting range
is 0 to 99 minutes (maximum limit). Note: In most applications, this setting will not need adjusting.
Press the SCROLL BUTTON to advance the next setting.
7. CYCLE 3 - FAST RINSE/BRINE REFILL
The control will display:
FILL/RNS: 3 min
11