Control - Introduction; Display; Operating Menu - Nibe GV-HR 130 Series Installer Manual

Ventilation heat exchanger
Hide thumbs Also See for GV-HR 130 Series:
Table of Contents

Advertisement

7 Control - Introduction

Display

Instructions, settings and operating information are
shown on the display. You can easily navigate between
the different menus and options to set the ventilation
or obtain the information you want.
The buttons on the display have various functions de-
pending on whereabouts you are in the menu system.

Operating menu

A
Speed
Extract
B
Extended
operation
C
Reheating
Main menu
The operating menu contains quick buttons for various
functions.
A
SPEED
Select the fan speed here (1-4). Switch off the fan
by pressing and holding the button for 3-4 seconds.
It is a precondition that Service menu, menu 28 -
"Stop the unit", is set to "on".
Speed 1
Reduced fan speed.
This mode is ideal when there is nobody at home.
The speed is set in Service menu, menu 10 - "Level
1 supply air" and menu 13 - "Level 1 exhaust air"
NIBE GV-HR 130
G
Temperature
F
Information
D
E
Filter
Speed 2
The fan's normal level.
The speed is set in Service menu, menu 11 - "Level
2 supply air" and menu 14 - "Level 2 exhaust air"
Speed 3
Forced fan speed.
This mode is ideal when there are a lot of people in
the home.
The speed is set in Service menu, menu 12 - "Level
3 supply air" and menu 15 - "Level 3 exhaust air"
Speed 4
Forced fan speed. The mode is ideal when you want
to lower the indoor temperature slightly, e.g. in the
summer.
The speed is 100% and cannot be set.
B
EXTENDED OPERATION
Here you activate a temporary increase in ventila-
tion.
In the event of a temporary increase in the ventila-
tion requirement, you can select an increase in
ventilation for an optional time (1-9 hours) in this
menu.
If the number of hours is set between 1 and 9, the
speed 3 will automatically connect back to speed 2
after the set number of hours.
Select speed 0 if you want to switch off the function
before the set number of hours has been reached.
C
REHEATING
Here you start or switch off any re-heater (external
component that is not supplied by NIBE).
If the symbol is set to +, the heater will be connec-
ted if necessary; if it is set to ÷, it will not be con-
nected, even if there is a need. It is a precondition
that User menu, menu 3 - "Reheating", is "on".
D
MAIN MENU
Here you enter the main menu.
E
FILTER
Here you reset filter alarm.
Chapter 7 | Control - Introduction
19