Checking The Rotor Thickness; Checking The Air Gap - Lenze m500-P Series Operating Instructions Manual

Three-phase ac motors
Table of Contents

Advertisement

Check the mounting dimension of the manual release
(
Stop!
Dimension "s" must be maintained! Check air gap "s
(^ operating instructions)
8.3.4

Checking the rotor thickness

}
Danger!
When the rotor thickness is checked, the motor must not run.
1. Remove fan cover and cover ring if attached.
2. Measure rotor thickness with calliper gauge. If a friction plate is attached, ensure
a flanged edge at the outer diameter of the friction plate.
3. Compare measured rotor thickness with minimally permissible rotor thickness
(values ^ 49).
4. If required, exchange the entire rotor. Description ^ 49.
8.3.5

Checking the air gap

1. Check the air gap "s
" near the fixing screws between the armature plate and
L
stator using a feeler gauge (^ 49).
2. Compare air gap measured to maximally permissible air gap "s
3. If required, set air gap to "s
Lenze ¯ BA 33.0008 ¯ 5.0
Size
s
(mm)
L
06
08
0.2
10
12
14
0.3
16
18
0.4
20
25
0.5
" (^ 48).
LN
Maintenance/repair
Maintenance operations
Checking the rotor thickness
"!
L
+0.1
s
(mm)
s + s
(mm)
L
1
1.2
1.5
1.8
2
2.4
2.5
3
" (^ 49).
L max.
8
47

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents