Figure 35: Pin wiring diagram for an RS-232 DCE transition cable to an AMPLIMITE 50-way connector.
D50 SCSI-2 Male
(to router)
Connect to backshell
Pin 1
Pin 26
D50 SCSI-2 Male — Pin View
Notes:
(1) → Output from router; ← Input to router.
(2) Use shielded cable with twisted pairs, e.g. UL2789 28AWG. Twisted pairing must be
1-26, 2-27, 3-28, etc.
(3) D25 connector shells to be metallised and fully shielded 360°.
(4) Standard cable length is 2.05m ± 0.05m.
(5) Ferrite must be fitted to cable no more than 25mm from rear of D50 SCSI-2 backshell.
(6) Cable version 4.0.
Cable Shield
RD
2
TD
12
CTS
3
RTS
14
DTR
13
SG
1
RL
15
TCG
20
DSR
4
FGND
21
FSELA
22
Pin 25
Ferrite
Pin 50
D25 Female
Insulating
Sheath
1
2
3
4
5
6
7
8
15
17
20
Pin 13
Cable
Pin 25
D25 Female — Pin View
AR Router
(to DTE)
Shield
TD
(103)
RD
(104)
RTS
(105)
CTS
(106)
DSR
(107)
SG
(102)
CD
(109)
TC
(114)
RC
(115)
DTR
(108)
Pin 1
Pin 14
A50R232C
C613-03031-01 REV E

Advertisement

Table of Contents
loading

Table of Contents