Service Parts Replacement; Blowers - Quadra-Fire CASTILE Series Owner's Manual

Pellet insert appliance
Hide thumbs Also See for CASTILE Series:
Table of Contents

Advertisement

5

Service Parts Replacement

A. Blowers
1. Combustion (Exhaust) Blower
PART NUMBER: 812-4400
a. If you have adequate clearance you will not have
to remove the panel set and disconnect flue, if not
then you will have to remove the panel set and
disconnect the flue.
b. Pull appliance out onto the hearth.
c. Remove right cast side.
d. Disconnect the white and blue wires from
the blower.
e. Remove blower mounting screws (not housing
bolts), Figure 25.1, from blower housing and
remove blower. The replacement blower is shipped
with a housing. If you do not need the housing,
discard it. If you do need to the replace the housing
you will also need to replace the gasket. See
Service Parts List for the part number.
f.
Re-install in reverse order.
Figure 25.1
25
Housing Bolts
(Do Not Remove)
Blower
Screws
7022-802J
2. Convection Blower
PART NUMBER: 812-4900
a. The blower is located at the bottom rear of the
insert. If an outside air kit is also installed, you
will first need to remove the outside air flange
by removing the 2 screws using a Phillips head
screwdriver. You do not need to remove the flex
pipe from the flange.
b. If you have adequate clearance you will not have
to remove the panel set and disconnect flue, if not
then you will have to remove the panel set and
disconnect the flue.
c. Pull appliance out onto the hearth.
d. Remove left cast side.
e. Disconnect the wires from the blower. The wires
coming from the wiring harness are purple & white
and the wires from the blower are black.
f.
The blower is held in place with a wing screw.
g. Re-install in reverse order.