Danfoss ADAP-KOOL AK-PC 781 Design Manual page 9

Capacity controller with heat recovery function, refrigeration control systems
Hide thumbs Also See for ADAP-KOOL AK-PC 781:
Table of Contents

Advertisement

1. Controller
Type
Function
Controller for capacity control of compressors and condensers
AK-PC 781
8 compressors with up to 3 unloaders, 8 fans, max. 120 inputs/outputs
2. Extension modules and survey of inputs and outputs
Type
Analog
inputs
For sensors, pres-
sure transmitters
etc.
Controller
11
Extension modules
AK-XM 101A
8
AK-XM 102A
AK-XM 102B
AK-XM 103A
4
AK-XM 204A
AK-XM 204B
AK-XM 205A
8
AK-XM 205B
8
AK-XM 208C
8
The following extension module can be placed on the PC board in the controller module.
There is only room for one module.
AK-OB 110
3. AK operation and accessories
Type
Function
Operation
AK-ST 500
Software for operation of AK controllers
-
Cable between PC and AK controller
Cable between zero modem cable and AK controller /
-
Cable between PDA cable and AK controller
-
Cable between PC and AK controller
Accessories
Power supply module 230 V / 115 V to 24 V d.c.
AK-PS 075
18 VA
AK-PS 150
36 VA
AK-PS 250
60 VA
Accessories
External display that can be connected to the controller module. For showing, say, the suction pressure
EKA 163B
Display
EKA 164B
Display with operation buttons
EKA 166
Display with operation buttons and LED for function cut in
AK-MMI
Graphic display with operation
Cable between display and controller
-
Cable between graphic display and controller
Accessories
Real time clock for use in controllers that require a clock function, but are not wired with data communication.
AK-OB 101A
Real time clock with battery backup.
Accessories
Communication modules for controllers where modules cannot be connected continuously
AK-CM 102
Communication module
On the following pages there is data specific to each module.
AK-PC 781
On/Off outputs
Relay
Solid state
(SPDT)
4
4
8
8
8
8
Capacity controller RS8GG602 © Danfoss 2015-03
On/off supply voltage
Analog
(DI signal)
outputs
Low voltage
High voltage
0-10 V d.c.
(max. 80 V)
(max. 260 V)
-
-
8
8
Application
Compressor / Condenser / Both/
Oil management / Heat recovery / CO2 gas
pressure
Stepper
Module with
output
switches
For valves
For override of
with step
relay outputs
control
-
4
4
2
Application
AK-operation
AK - Com port
AK - RS 232
AK - USB
Supply for controller
Length = 2 m, 6 m
Length = 1.5 m, 3.0 m
To be mounted in an AK controller
Data communication for external extension
modules
-
x
x
9