Download Print this page
Nidec PG-100B Series Instruction Manual

Nidec PG-100B Series Instruction Manual

Handy manometer

Advertisement

Quick Links

HANDY MANOMETER
PG-100B
Series
Instruction Manual
Ver.2.1
Important Information and Warnings
CAUTION
Operating Precautions
(1) The applicable media are gases/liquids compatible with SUS316L.
Materials of the pressure port are SUS316L while those of the attachment are SUS316 and SUS 304. So please be careful about compatibility with 
applicable media. 
Use of corrosive fluids may cause injury and/or malfunction of products.
In addition, the product is not explosive-proof. Never use flammable fluid as media.
(2) Maintain the measuring pressure within the pressure range as stated in specifications.
Pressures exceeding the maximum pressure rating may cause product failure.
(3) Be careful not to let any liquid inside the main product.
Liquid leak on the pressure port may cause product failure. So please be careful to remove fluids completely before detaching relevant fitting and/or 
tube from the pressure port.
(4) Be careful not to mix foreign materials in the pressure port.
Mixing a foreign material in the port may cause product failure or air leakage. If there is a possibility of mixing foreign materials into the port, use 
the product with a filter.
(5) Be aware of possibilities of accidents related to the strap.
Swinging the product intentionally in the air by holding the strap may result in unexpected accidents, injury or product damage. Be sure to use the 
product with its main body gripped firmly.
(6) Be careful not to give external shocks to the products.
External shocks such as hitting and dropping may cause product failure.
(7) Installation of attachments
When installing an attachment to the pressure port, the tightening torque should be set at around 1 N ・ m. Make sure to use"insert ring" ( attachment)
when you pour liquid into a tube connected with"one-touch fitting" ( attachment) .
(8) Attention for analog output function using.
No voltage or signal should be applied to the CAL terminal by tha faulty wiring. Failure to heed this warning may result in product malfunction or 
damage to the main body.
Moreover, do not lose the battery cover when the analog output function is used.
(9) Caution for handling of protect cover
The protect cover is made of silicon rubber. Never use fluids as media which are not compatible with the silicon rubber. The main purpose of the 
protect cover is to prevent liquid leak into the main body when the attachment and tube are detached from the product. It doesnʼt serve as drip-proof, 
so please wipe off in case any liquid leak takes place.
This caution mark indicates a chance of physical damages to the user and/or the product 
if it is used improperly and/or incorrectly. The damage can be substantial. 
●The  product  is  not  explosion-proof.  Do  not  use  the  product  in  designated  areas  where 
explosion-proof specification is required.
●The product is not drip-proof /dust-proof. 
●The product is designed for measurement of intended articles and does not feature control 
functions that ensure security, such as prevention of accidents.
Thank you for purchasing NIDEC COPAL ELECTRONICS 
CORP. product.
In order to use the product correctly and most appropriately, 
please  completely  read  this  manual  before  use  and  keep  it 
for future reference.
For inquiries regarding the product, please contact:
Head Office: Nishi-Shinjuku Prime Square, 
7-5-25 Nishi-Shinjuku, Shinjuku-ku, Tokyo 160-0023, Japan
https://www.nidec-copal-electronics.co
1

Advertisement

loading

Summary of Contents for Nidec PG-100B Series

  • Page 1 Thank you for purchasing NIDEC COPAL ELECTRONICS  HANDY MANOMETER CORP. product. In order to use the product correctly and most appropriately,  PG-100B please  completely  read  this  manual  before  use  and  keep  it  for future reference. Series For inquiries regarding the product, please contact: Head Office: Nishi-Shinjuku Prime Square,  Instruction Manual 7-5-25 Nishi-Shinjuku, Shinjuku-ku, Tokyo 160-0023, Japan https://www.nidec-copal-electronics.co Ver.2.1 Important Information and Warnings This caution mark indicates a chance of physical damages to the user and/or the product  if it is used improperly and/or incorrectly. The damage can be substantial.  CAUTION ●The  product  is  not  explosion-proof.  Do  not  use  the  product  in  designated  areas  where ...
  • Page 2: Maintenance Precautions

    Maintenance Precautions (1) Periodic maintenance check should be carried out. Make sure the product operates normally before using. Unexpected event may cause product failure and affect its basic function.. (2) Do not disassemble or modify the product. Unauthorized disassembly or modification may result in a malfunction. The product warranty does not cover failures caused by disassembly and/or  modification of the product. (3) The batteries used are AAA manganese dry cells or AAA alkaline dry cells. Use of batteries other than as stated above may cause product failure. (4) Insert the batteries to contact the correct positive and negative terminals. Insertion  of  the  battery  in  the  wrong  direction  may  induce  rupture  or  electrolyte  leakage  of  the  battery,  resulting  in  product  failure.  When  the  product is intended not to be used for a long period of time, remove the battery from it in order to prevent electrolyte leakage. (5) Stains on the product should be wiped off with a soft, dry cloth. Stains on the product should be wiped off with a cloth immersed in a neutral detergent diluted with water and squeezed well; dry with a soft cloth. At  this time, be careful not to allow the neutral detergent solution to enter the pressure port and/or main body. Infiltration of the neutral detergent may ...
  • Page 3: Specifications

    Specifications Model PG-100B Pressure range 102R 103R 102A Type Gauge Absolute −100〜100kPa −100〜1000kPa 0〜100kPa abs. Rated pressure (−750〜750mmHg) (mmHg undisplayable) (mmHg undisplayable) Max. pressure 200kPa 1500kPa 200kPa abs. 3-1/2-digit LCD Indication system Resolution 1digit Indication unit kPa, MPa, mmHg, in.Hg, mmAq, psi, bar* Zero adjustment, Hold, Offset, Auto power off, Unit switching Function Indication accuracy(at 25℃) ±0.5%F.S.±2digits Indication accuracy(at 25±25℃) ±1.0%F.S.±2digits ±2.0%F.S.±2digits Gases/Liquids compatible with SUS316L Available media Operating temp. 0℃ to 50℃ (No freezing) Operating humidity 15 to 85% RH or below (No condensing)...
  • Page 4 Operation Method/Functional Explanation [Insertion of Batteries] Slide the battery cover on the back of the product body downward to open the cover. Insert the batteries in the direction  as illustrated, check that the batteries are correctly and firmly in place, and slide the battery cover again to close. [Operation Method] (1) Turning the power ON  With  the  power  turned  off,  press  the    POWER    button  under  open  air  atmospheric  pressure,  and  check  that  the  minimum digit for the pressure indication is within 0±10 digits. (For the pressure range “102A”, 100 ( kPa abs.) will  be displayed when the power button is turned on under atmospheric pressure.) (2) Zero adjustment  After  turning  on  the  power,  if  a  difference  is  detected  between  the  zero  values  in  open  air  atmospheric  pressure,  press ...
  • Page 5: Warranty

    Analog Function Open the battery cover on the back of the main body and insert the pre-wired connector according to the table shown below. After applying external power,  press the  POWER  button to turn on the power. Be sure to use the product with the batteries removed. The mode will not switch to the analog output  mode unless the batteries are removed. Connector Connector No. Description 6     1 1 External power input  (5V) Analog output terminal  (±1V) 2 3 4 5 6 Manufacturer Housing Contact Wire gauge SZH-002T-P0.5 AWG28〜26 JST Mfg. Co., Ltd. ZHR-6 SZH-003T-P0.5 AWG32〜28 Analog voltage as indicated will be output to the analog output terminal. Pressure range, rated pressure and output voltage are shown to the table below. No voltage or signal should be applied to the CAL terminal since it is for adjustment use only. Failure to heed this warning may result in product malfunction or damage to the main body. Pressure range Rated pressure [ kPa] Output voltage  [V] 102R −100.0〜100.0 −1.000〜1.000 103R   −100〜1000...

This manual is also suitable for:

Pg-100b-102r-mx1tPg-100b-103r-mx1tPg-100b-102a-mx1tPg-100b-102r-hx1tPg-100b-103r-hx1tPg-100b-102a-hx1t ... Show all