Digital pressure gauge

Advertisement

Quick Links

DIGITAL PRESSURE GAUGE
PG-200
INSTRUCTION MANUAL   
This caution mark describes when there is a possibility that user may suffer from damage or physical damage may occur if the product is used improperly.
WARNING
These products (pressure sensors, pressure switches, pressure gauges, pressure indicators, leakage sensors, etc.) are designed and manufactured as general industrial 
parts. Therefore, a person with sufficient knowledge and experience shall confirm the conditions and environments described in the catalog, specifications, and 
instruction manual of each product, check the suitability of the product for the machine, device, or system which you use, and ensure safety before use.
These products are not intended to be used for applications particularly requiring high reliability (These include, but are not limited to, nuclear power control, 
aerospace and military purposes).
The details of warranty shall be as per the descriptions in this document and we shall not be liable for any damage on you resulting from the use of any equipment or 
device (including control systems) which is not in accordance with this document (hereinafter referred to as "use in violation"). In the case where you resell our 
products, we shall not be liable for any damage on a third party resulting from use in violation by the third party, and even if we make payment to the third party in 
connection with such use in violation regardless of the name by which such payment may be called, we may demand the whole amount thereof from you. 
1. Handling Note
§
CAUTION
CAUTION
⑴Mounting the attachment for panel type
 If fightenig the attachment to the pressure port, the tightening torque should be around 1 N・m.
⑵Piping for stand-alone type
 For piping, use the hexagonal portion of the pressure port for driving.
⑶Media to be used
 The Pressure Gauge should be used for fluids that cannot corrode the diaphragm of SUS316L, pressure port of SUS 316 and O-ring of fluoro rubber.
⑷Excessive pressure
 The  pressure  to  be  measured  is  within  the  specified  range.  Measurement  of  a  higher  pressure  than  the  maximum  allowable  one  may  cause  performance 
degradation or destruction.
⑸Internal battery
①Replace battery with Toshiba Battery Co.,Ltd./ERVM3.6V/lithium battery only. Use of another battery may present a risk of fire or explosion. If you need 
replace battery, please place an order with us.
②When "LOBAT" sign is displayed, the battery should be replaced.
③The battery used in this device may present risk of fire of chemical burn if mistreated. Do not recharge, disassemble, heat above 100℃(212°F), or incinerate.
④Dispose of used battery promptly. Keep away from children. Do not disassemble and do not dispose of in fire.
⑹Maintenance
 If the Pressure Gauge gets dirty, wipe it off with hardly squeezed cloth containing a neutral detergent. Do not use any thinner and benzine.
⑺Protection against noises
①Noises having mixed in the switch output or power line may cause the Pressure Gauge to change the pressure indication, malfunction or be broken.
 Take some measure to put the Pressure Gauge away from power line or use shielded wire. It is effective to ground the Pressure Gauge.
②If  the  switch  output  has  an  induction  load  such  as  relay  or  solenoid  connected  to  it,  it  should  have  a  surge  absorber  circuit  put  in  it.  The  relay  contacts 
should have a contact preventive circuit put in it to prevent noises from being generated.
⑻Prohibition of short-circuiting the switch terminals
 Do not short-circuit the switch output terminal to any power terminal. The internal circuit may be broken.
You are greatly appreciated for purchasing 
NIDEC COMPONENTS CORP. Model PG−200 digital 
Pressure Gauge. You should read this instruction manual 
thoroughly to operate the PG−200 in optimum state.
Ver.8.0
WARNING
WARNING
This caution mark describes when there is a possibility that user may suffer from damage or physical 
damage may occur if the product is used improperly.
For more detailed information please ask for the
nearest distributor or the following sales center.
Nishi-Shinjuku Prime Square bldg., 7-5-25
Nishi-Shinjuku, Shinjuku-ku,Tokyo 160-0023, Japan
Phone: +81-3-3364-7055  Fax: +81-3-3364-7098
URL :  https://www.nidec-components.com
1

Advertisement

loading

Summary of Contents for Nidec PG-200

  • Page 1 You are greatly appreciated for purchasing  NIDEC COMPONENTS CORP. Model PG−200 digital  DIGITAL PRESSURE GAUGE Pressure Gauge. You should read this instruction manual  thoroughly to operate the PG−200 in optimum state. PG-200 For more detailed information please ask for the nearest distributor or the following sales center. Nishi-Shinjuku Prime Square bldg., 7-5-25 Nishi-Shinjuku, Shinjuku-ku,Tokyo 160-0023, Japan Phone: +81-3-3364-7055  Fax: +81-3-3364-7098 INSTRUCTION MANUAL    Ver.8.0 URL :  https://www.nidec-components.com This caution mark describes when there is a possibility that user may suffer from damage or physical damage may occur if the product is used improperly. WARNING WARNING WARNING These products (pressure sensors, pressure switches, pressure gauges, pressure indicators, leakage sensors, etc.) are designed and manufactured as general industrial  parts. Therefore, a person with sufficient knowledge and experience shall confirm the conditions and environments described in the catalog, specifications, and  instruction manual of each product, check the suitability of the product for the machine, device, or system which you use, and ensure safety before use. These products are not intended to be used for applications particularly requiring high reliability (These include, but are not limited to, nuclear power control,  aerospace and military purposes). The details of warranty shall be as per the descriptions in this document and we shall not be liable for any damage on you resulting from the use of any equipment or  device (including control systems) which is not in accordance with this document (hereinafter referred to as "use in violation"). In the case where you resell our  products, we shall not be liable for any damage on a third party resulting from use in violation by the third party, and even if we make payment to the third party in  connection with such use in violation regardless of the name by which such payment may be called, we may demand the whole amount thereof from you.  1. Handling Note § CAUTION This caution mark describes when there is a possibility that user may suffer from damage or physical  damage may occur if the product is used improperly. CAUTION ⑴Mounting the attachment for panel type  If fightenig the attachment to the pressure port, the tightening torque should be around 1 N・m.
  • Page 2 2. TRANSPORTATION & STORAGE  § ⑴The product, which is a precision instrument, must be taken special care not to be damaged by impact nor by being dropped when it is trasported and in storage. ⑵The product must be avoided in storage where is dusty, dripping and vibrated. 3. Specification § ⑴Model Table 1 Break-down SERIES PRESSURE RANGE Pressure RESOLUTION UNIT PG−200 −        − PRESSURE  101G 0〜1000 2000 5000 101GP 0〜10.00 0.01 102G 0〜1.000 0.001 kgf/cm Series name Series ( Table 1) Type ( Table 2) 102GP 0〜100.0 102VP 0〜−100.0 0〜−735 1471 3678...
  • Page 3 4. Exterminal Dimensions  § tolerance(±0.5mm) [Panel type] [Stand-alone type] Unit of display Pressure port Panel cut M5, depth 5 R1/4 Panel thickness Panel montng hook (PT1/4) (1〜2.5mm) M5 ( P=0.8) depth6 ⑴Mounting onto panel  Cut a hole out as shown in the panel cut drawing above. Forcibly put the  main body into the cut hole. The hook will fix the main body to the panel. ⑵Removing out of panel  Draw the main body out of the panel while nipping the hook between your  thumb and middle fingers. 5. Terminal Wiring § [Panel type] [Stand-alone type]   Proceed on the PC boad inside the main body. } ・5〜10V + External power models ・COM. − ・10〜24V + Terminal block of 6 pins ・COM.
  • Page 4 7. Front Panel Controls and Features § ⑴Front panel controls Front controls Pressure indicator Battery change indicator Polarity indicator Switching indicator Decimal point ZERO adjusting trimmer POWER switch SPAN adjusting SET switch LO setting HI setting trimmer trimmer trimmer ⑵Description of the features Pressure indicator Shows a pressure value entered to the pressure port. Also shows a set value given with the set switch. Polarity indicator Shows the negative(−)upon negative pressure. Pressure port Has a pressure applied. POWER switch Turns on or off the power to the Pressure Gauge. SET switch Selects a mode to check a HI or LO set value. If you press the SET switch once, the indication will be automatically changed in the  sequence shown below. To check the LO set value, wait for around 20 seconds after pressing the SET switch. Pressure HI setting LO setting indicaton Around 20 sec Around 20 sec Indication mode Setting mode If setting ends or to interrupt setting in the course, press the SET switch again. Then the pressure will be indicated.