Cable Preparation Receiving Sides; Grounding Instrument - JRC AlphaWind AlphaLine Series Installation And Operation Manual

Wind repeater
Table of Contents

Advertisement

Figure 6: Cable Preparation Sending Cable Sides
Note Always check the drawing for the correct shielding of signals.

1.1.8.2 Cable Preparation Receiving Sides

1. Remove approx. 80 mm of the plastic cable sheath, including the grounding shield.
2. Wrap insulating tape over the cable end.
3. Attach the isolated cable end to the metal saddle on the rear of the instrument. See Figure 7: Cable Preparation
Receiving Cable Sides on page 14.
Figure 7: Cable Preparation Receiving Cable Sides
Note Always check the drawing for the correct shielding of signals.

1.1.9 Grounding Instrument

To function properly, the AlphaLine instrument must be grounded to the ship's mass.
For this purpose the instrument has a grounding bolt. Connect the grounding bolt to the ship's mass with a low
impedance connection.
14 | Installation Instructions

Advertisement