Instrument Electric Connections; Cable; Cable Preparation; Cable Preparation Sending Sides - JRC AlphaWind AlphaLine Series Installation And Operation Manual

Wind repeater
Table of Contents

Advertisement

INFO: Pay special attention to the small protruding cam, so that it fits exactly in the gap in the front panel.
5. Place the instrument in the bracket.
6. Mount the 4 lock washers and hex nuts.

1.1.6 Instrument Electric Connections

All AlphaLine instrument versions share the same electronics with identical connections.
For pin-outs, see Table 4: Serial Connector P12 (8 pins) on page 18 and Table 5: Serial Connector P19 (12 pins) on
page 18.

1.1.7 Cable

Use the following connection cables:
Name
Specification
Power
2 x 1.5 mm
USB
USB
3 x 2 x 0.5 mm
Serial
3 x 2 x 0.75 mm
2 x 2 x 0.5 mm
Serial
2 x 2 x 0.75 mm
Ethernet
Ethernet CAT 5e S/FTP
Table 3: Connection Cables

1.1.8 Cable Preparation

Cable preparation and cable connections as described in this manual are essential for the correct functioning of the
instrument.
Note There are two type of cable sides (connections): sending cable sides and receiving cable sides. Normally,
the cable shield will be grounded only at the sending side of the cable. For a power cable, this is the power
supply side. For a data cable, this is the Tx side of the cable. For combined Tx/Rx cables, either side can be
grounded, but beware of grounding only one side.

1.1.8.1 Cable Preparation Sending Sides

1. Remove approx. 80 mm of the plastic cable sheath, including the grounding shield.
2. Cut away approx. half of the length of the now visible cable shield and fold the remaining shield back over the cable
sheath.
3. Wrap insulating tape over half of the visible grounding shield.
4. Attach the remaining visible grounding shield to the metal saddle on the rear of the instrument. See Figure 6: Cable
Preparation Sending Cable Sides on page 14.
13 | Installation Instructions
2
2
(inside cabinets)
2
(ship's cabling)
2
(inside cabinets)
2
(ship's cabling)
Shield
Norm
(Y/N)
Y
IEC 60092-352
Y
IEC 61162-2
Y
Y
IEC 61162-1
Y