24 in. min.
(508 mm)
(610 mm)
Lowest
Discharge
Opening
Termination
Cap
Storm Collar
Roof
Flashing
Roof Pitch
H (Min.) Ft.
Flat to 6/12
1.0*
Roof Pitch
H (Min.) Ft.
Flat to 6/12
1.0*
Over 6/12 to 7/12
1.25*
Over 6/12 to 7/12
1.25*
Over 7/12 to 8/12
1.5*
Over 7/12 to 8/12
1.5*
Over 8/12 to 9/12
2.0*
Over 8/12 to 9/12
2.0*
Over 9/12 to 10/12
2.5
Over 9/12 to 10/12
2.5
Over 10/12 to 11/12
3.25
Over 10/12 to 11/12
3.25
* 3 ft. minimum in snow regions
* 3 Feet. Minimum in Snow Regions
Figure 3.18 - Minimum Height from Roof to Lowest Discharge
Opening
Class A Metal Chimney
Prior to installing the gas stove, ensure that the existing
chimney is functionally sound and clean.
Have the chimney and adjacent structure inspected
and cleaned by qualified professionals. Hearth & Home
Technologies recommends that NFI or CSIA certified
professionals, or technicians under the direction of
certified professionals, conduct a minimum of a NFPA
211 Level 2 inspection of the chimney.
Replace component parts of the chimney and fireplace
as specified by the professionals.
2121
Horizontal
overhang
20 in.
Vertical
wall
X
12
Roof Pitch
is X / 12
H (min.) - Minimum height
from roof to lowest
discharge opening.
Roof Pitch
H (Min.) Ft.
Over 11/12 to 12/12
Roof Pitch
H (Min.) Ft.
Over 11/12 to 12/12
4.0
Over 12/12 to 14/12
Over 12/12 to 14/12
5.0
Over 14/12 to 16/12
Over 14/12 to 16/12
6.0
Over 16/12 to 18/12
Over 16/12 to 18/12
7.0
Over 18/12 to 20/12
7.5
Over 18/12 to 20/12
Over 20/12 to 21/12
8.0
Over 20/12 to 21/12
Vermont Castings • Stardance SDDVT Installation Manual_R23 • 11/21
Existing Metal
Chimney System
Direct Vent Pipe
(Length as required)
4.0
5.0
Figure 3.19
6.0
1. Remove existing chimney cap.
7.0
7.5
2. Measure the distance from the top of the chimney to the
bottom of the ceiling support box, add 3 in. (76mm) to
8.0
this measurement, and cut a section of 4 in. (101mm)
flex pipe to that length (the flex should be fully extended).
3. Connect the end of the flex pipe section to the underside
of the top adapter, using four sheet metal screws. See
Figure 3.20.
4. Pass the flex pipe down through the center of the
chimney system, and center the top adapter on the top
of the chimney pipe. Drill four 1/8 in. (3mm) diameter
holes through the top adapter, and into the chimney
top. Ensure that you are drilling into the metal on the
chimney. Twist lock the high wind termination cap onto
the top adapter. See Figure 3.21 and Figure 3.22.
4" Flex Pipe
(Included in Link-Stove Kit)
Figure 3.20
Termination Cap
(Includ. in Link-Stove Kit)
Top Adaptor
(Includ. in Link-Stove Kit)
Flashing
(Includ. in Link-Stove Kit)
4 in. (102mm) Flex Pipe
(Includ. in Link-Stove Kit)
Retro Connector
(Includ. in Link-Stove Kit)
Top Adapter
(Included in Link-Stove Kit)