red lion CSDIO Manual

red lion CSDIO Manual

Modular controller

Advertisement

Quick Links

MODEL CSDIO - MODULAR CONTROLLER
U L
C
US LISTED
R
IND. CONT. EQ.
34AD
U L
FOR USE IN HAZARDOUS LOCATIONS:
C
US
R
Class I, Division 2, Groups A, B, C, and D
LISTED
IND.CONT. EQ.
3PWL
For Model No. CSDIO14S Only
GENERAL DESCRIPTION
The Model CSDIO series modules are digital I/O modules designed for use
with the Modular Controller Series. The CSDIO14 offers eight inputs and six
outputs that can be used to monitor contact or sensor inputs and actuate relays,
solenoids, PLC inputs, etc.
The inputs accept standard DC inputs or contact closures, and are configured
for Sink/Source signals via external switches. Additionally, each input has a
switch selectable input filter that can be used to prevent contact bounce. Each
input may also be software configured as a high-active or low-active input.
The modules are available with relay or NFET outputs that are capable of
switching up to one amp each (NFET DC only). For applications requiring large
loads to be controlled, several DIN rail mount relays are available.
The CSDIO modules connect and communicate via a backplane connection
to the CSMSTR Modular Controller Series Master. The CSMSTR, equipped
with serial ports as well as an Ethernet port, allows the system to share data with
PCs, PLCs, and SCADA systems. The Master supports any combination of up
to 16 CS Series modules.
Internal power management circuits allow the modules to be replaced while
power is applied, which reduces downtime in the event of a relay failure. All
configuration information is stored locally within each module, as well as in the
DIMENSIONS In inches (mm)
1.24
(31.5)
4.98
(126.5)
13
7
1
4.17 (105.9)
1
SERIES DIGITAL MODULE
 ADDS REMOTE I/O CAPABILITY TO THE MODULAR
CONTROLLER SERIES
 EIGHT INPUT, SIX OUTPUT DIGITAL MODULE
 INPUTS ISOLATED FROM OUTPUTS
 INPUTS INDEPENDENTLY SWITCH SELECTABLE FOR SINK OR
SOURCE SIGNALS
 INPUTS INDEPENDENTLY CONFIGURABLE FOR HIGH OR LOW
ACTIVE STATE
 INPUTS INDEPENDENTLY SWITCH SELECTABLE FOR HIGH OR
LOW FREQUENCY SIGNALS
 RELAY OR NFET OUTPUT MODELS AVAILABLE
Master, so replacement modules do not need to be configured. The Modular
Controller Series' high density packaging and DIN rail mounting saves time and
panel space. The backplane connection provides power and communication to
the module and snaps easily onto standard top hat (T) profile DIN rail.
CONFIGURATION
The Modular Controller Series is configured with Windows
®
Crimson
software. The software is an easy to use, graphical interface that
provides a means of communication configuration, as well as commissioning
and calibration of new systems.
SAFETY SUMMARY
All safety related regulations, local codes and instructions that appear in the
manual or on equipment must be observed to ensure personal safety and to
prevent damage to either the instrument or equipment connected to it. If
equipment is used in a manner not specified by the manufacturer, the protection
provided by the equipment may be impaired.
Do not use the module to directly command motors, valves, or other actuators
not equipped with safeguards. To do so can be potentially harmful to persons or
equipment in the event of a fault to the module.
CAUTION: Risk of Danger.
Read complete instructions prior to
installation and operation of the unit.
WARNING - EXPLOSION HAZARD - SUBSTITUTION OF
COMPONENTS MAY IMPAIR SUITABILITY FOR CLASS I,
DIVISION 2
THIS EQUIPMENT IS SUITABLE FOR USE IN CLASS I,
DIVISION 2, GROUPS A, B, C, D, OR NON-HAZARDOUS
LOCATIONS ONLY
Bulletin No. CSDIO-J
Drawing No. LP0558
Released 05/15
®
compatible
CAUTION: Risk of electric shock.

Advertisement

Table of Contents
loading

Summary of Contents for red lion CSDIO

  • Page 1 Master, so replacement modules do not need to be configured. The Modular Controller Series’ high density packaging and DIN rail mounting saves time and The Model CSDIO series modules are digital I/O modules designed for use panel space. The backplane connection provides power and communication to with the Modular Controller Series.
  • Page 2: General Specifications

    8. COMMUNICATIONS: Provided by the CS Master 9. ENVIRONMENTAL CONDITIONS: 1. POWER: Derived from system backplane. (CSDIO draws 170 mA max. load Operating Temperature Range: 0 to +50 °C on power input of MASTER). Modules may be hot-swapped (replaced while Storage Temperature Range: -40 to +85 °C...
  • Page 3: Emc Installation Guidelines

    Visit RLC’s web site at http://www.redlion.net/emi for more information on and portable two-way radios are used in close proximity or if the installation EMI guidelines, Safety and CE issues as they relate to Red Lion Controls is near a commercial radio transmitter. Also, Signal or Control cables within products.
  • Page 4: Hardware Installation

    HARDWARE INSTALLATION ATTACH THE MODULE BASE ATTACH MODULE TO BASE SEPARATE BASE TO THE DIN RAIL FROM MODULE MODULE BASE MODULE BASE WIRING WIRING CONNECTIONS WARNING - EXPLOSION HAZARD - DO NOT DISCONNECT All conductors should meet voltage and WHILE CIRCUIT IS ALIVE UNLESS AREA IS KNOW TO BE current ratings for each terminal.
  • Page 5: Firmware Upgrade

    LEDS ALM – ALARM LED The Alarm LED indicates the presence of a fault condition. STS – STATUS LED The Status LED is a dual color LED that provides information regarding the FIRMWARE UPGRADE state of the module. This includes indication of the various stages of the start-up The module’s firmware is stored in flash memory so that software/hardware routine (power-up), as well as any errors that may occur.
  • Page 6 This page intentionally left blank...
  • Page 7 This page intentionally left blank...
  • Page 8: Limited Warranty

    The Company disclaims all liability for any affirmation, promise or representation with respect to the products. The customer agrees to hold Red Lion Controls harmless from, defend, and indemnify RLC against damages, claims, and expenses arising out of subsequent sales of RLC products or products...

This manual is also suitable for:

Csdio14rCsdio14s

Table of Contents