④ Disassemble the
electrical box
⑤ Disassemble the
baffle at the pipe
outlet.
⑥ Disassemble the
water pump
Unit MAINTENANCE
58
Loosen two screws on the cover of the
electric box and then remove it away.
Disconnect the wiring terminals of the motor
and the temperature sensing bulb, then
loosen two screws fixing the electric box,
after that, remove the electric box away.
Loosen two screws on the baffle and take it
out by turning it upward.
Loosen the screws fixing the drain pan and
then take the it out upward.