Drive Components

Removing the Dust Cover
1)
Cut dust cover seal. Remove the dust cover screws with a standard flathead screwdriver.
2)
Note the setting on calibration adjuster.
3)
Note the position of the drive gear (either above or below the packing gland pinion).
1
Removing the Adjuster
1)
Loosen the retaining screws using a standard flathead screwdriver.
2)
Slide the retaining clip up and over to the right side.
1
3)
From the top, remove the screws to adjuster plate.
4)
Lift adjuster out of the counter adapter.
5)
Remove the adjuster drive assembly.
3
Page 32
2
2
4
Check us out at www.TCSmeters.com!
3
5
TCS900003, Rev.6